Skip to main content
  1. Home >
  2. Products >
  3. Computing Products >
  4. Servers >
  5. Fujitsu SPARC servers >
  6. Downloads >
  7. User Manuals >
  8. Fujitsu SPARC M12-2/M12-2S Service Manual >
  9. 6.2.5 Active/Cold Removal Workflow of the PCI Expansion Unit

6.2.5 Active/Cold Removal Workflow of the PCI Expansion Unit


6.2.5 Active/Cold Removal Workflow of the PCI Expansion Unit
You can perform active/cold removal of a PCI expansion unit in the following configuration:
  1. Configuration connecting two or more SPARC M12-2S units to a physical partition
Table 6-8 shows the workflow for active/cold removal of a PCI expansion unit.
Table 6-8  Active/Cold Removal Procedure of a PCI Expansion Unit
Work Order Task Reference
1 Checking the operating condition of the system "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
2 Checking the logical domain assignment status of CPU resources mounted in the SPARC M12-2S requiring maintenance "3.2.4 Checking the Assignment Status of Resources" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide
3 Checking the logical domain assignment status of memory resources mounted in the SPARC M12-2S requiring maintenance "3.2.4 Checking the Assignment Status of Resources" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide
4 Releasing the logical domain assignment of all the PCIe cards and HDD/SSD mounted in the SPARC M12-2S requiring maintenance and the PCI expansion unit "9.3 Releasing I/O Resources From a Logical Domain"
5 Releasing the HDD/SSD and PCIe cards mounted in the SPARC M12-2S requiring maintenance and the PCI expansion unit, from the system "9.4 Enabling the Removal of Hardware"
6 Releasing the SPARC M12-2S requiring maintenance from the physical partition "9.4.3 Dynamically Releasing the SPARC M12-2S From the Physical Partition"
7 Switching the mode switch on the OPNL to Service "2.3.2 OPNL Control Function"
8 Confirming that the physical partition and logical domains continue operating "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
9 Releasing the SPARC M12-2S requiring maintenance from the building block configuration "9.6.1 Releasing the SPARC M12-2S From the Building Block Configuration"
10 Releasing the PCI expansion unit to be removed and the link card "11.3 Removing a Link Cable" in the PCI Expansion Unit for Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Service Manual
11 Removing the PCICS in which the link card is mounted from the SPARC M12-2S "12.3.1 Enabling the Removal of a PCIe Card"
12 Removing the link card from the PCICS "12.3.2 Removing a PCIe Card or PCIe Card Filler"
13 Installing a PCIe card filler in the PCICS from which the link card was removed, and installing the PCICS in the SPARC M12-2S "12.4.1 Installing a PCIe Card or PCIe Card Filler"
14 Incorporating the SPARC M12-2S from which the PCI expansion unit was removed into the building block configuration "10.4.1 Incorporating the SPARC M12-2S Into a Building Block Configuration"
15 Incorporating the SPARC M12-2S from which the PCI expansion unit was removed into the physical partition "10.6.1 Incorporating the SPARC M12-2S Into the Physical Partition Using PPAR DR"
16 Switching the mode switch on the OPNL to Locked "2.3.2 OPNL Control Function"
17 Checking the operating condition of the physical partition and logical domains (*1) "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
18 Saving logical domain configuration information "9.1.1 Saving Logical Domain Configuration Information"
*1 Reassign I/O resources to logical domains as required. For details, see "3.2.4 Checking the Assignment Status of Resources" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide.