You can perform inactive/cold addition of the HDD/SSD in the following configuration:
  1. Building block configuration where two or more physical partitions are operating
Table 5-14 shows the workflow for inactive/cold addition of the HDD/SSD.
Table 5-14  Inactive/Cold Addition Procedure of the HDD/SSD
Work Order Task Reference
1 Checking the operating condition of the system "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
2 Powering off the physical partition containing the SPARC M12-2S requiring maintenance "9.5.1 Stopping a Specific Physical Partition"
3 Switching the mode switch on the OPNL to Service "2.3.2 OPNL Control Function"
4 Releasing the SPARC M12-2S requiring maintenance from the building block configuration, and removing the power cords "9.6.1 Releasing the SPARC M12-2S From the Building Block Configuration"
"9.8.2 Removing the Power Cords"
5 Removing the filler unit from the SPARC M12-2S "15.3.2 Removing a Filler Unit"
6 Installing an HDD/SSD in the SPARC M12-2S "15.4.1 Installing an HDD/SSD"
7 Installing the power cords on the SPARC M12-2S with the added HDD/SSD, and incorporating it into the building block configuration "10.1.1 Installing a Power Cord"
"10.4.1 Incorporating the SPARC M12-2S Into a Building Block Configuration"
8 Diagnosing the SPARC M12-2S with the added HDD/SSD "10.5.1 Diagnosing the SPARC M12 Hardware"
9 Confirming that there is no problem with the added HDD/SSD "10.5.3 Checking the FRU Status After Maintenance"
10 Switching the mode switch on the OPNL to Locked "2.3.2 OPNL Control Function"
11 Powering on the physical partition of the added HDD/SSD "10.9.1 Starting the System With an XSCF Command"
12 Assigning the I/O resource to a logical domain "3.2 Operations and Commands Related to Logical Domain Configurations" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide