4.4.16 Inactive/Cold Replacement Workflow of the XSCF DUAL Control Cable
4.4.16 Inactive/Cold Replacement Workflow of the XSCF DUAL Control Cable
You can perform inactive/cold replacement of the XSCF DUAL control cable in the following configuration:
- Building block configuration where two or more physical partitions are operating
Table 4-44 shows the workflow for inactive/cold replacement of the XSCF DUAL control cable.
Work Order | Task | Reference |
---|---|---|
1 | Checking the operating condition of the system | "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains" |
2 | Confirming the XSCF DUAL control cable to be replaced | "8.2 Troubleshooting" |
3 | Checking the operation status of the SPARC M12-2S connected to the XSCF DUAL control cable to be replaced | "8.1.2 Checking Hardware" |
4 | Powering off the physical partition containing the SPARC M12-2S connected to the XSCF DUAL control cable requiring maintenance | "9.5.1 Stopping a Specific Physical Partition" |
5 | Switching the mode switch on the OPNL to Service | "2.3.2 OPNL Control Function" |
6 | Releasing the SPARC M12-2S requiring maintenance from the building block configuration | "9.6.1 Releasing the SPARC M12-2S From the Building Block Configuration" |
7 | Placing the SPARC M12-2S requiring maintenance into the cold state, and removing the XSCF DUAL control cable from the SPARC M12-2S | "21.3 Removing the XSCF DUAL Control Cable" |
8 | Installing the XSCF DUAL control cable, which is a maintenance part, on the SPARC M12-2S, and placing the SPARC M12-2S that required maintenance into the hot state | "21.4 Installing the XSCF DUAL Control Cable" |
9 | Incorporating the SPARC M12-2S that required maintenance into the building block configuration | "10.4.1 Incorporating the SPARC M12-2S Into a Building Block Configuration" |
10 | Confirming that there is no problem with the replacement XSCF DUAL control cable | "10.5.3 Checking the FRU Status After Maintenance" |
11 | Switching the mode switch on the OPNL to Locked, and powering on the physical partition containing the SPARC M12-2S that has undergone maintenance | "10.8 Powering on a Physical Partition" |
12 | Checking the operating condition of the system | "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains" |