Skip to main content

8.1.6 Checking FRU Information


8.1.6 Checking FRU Information
FRU information includes detailed information on hardware. Log in to the XSCF shell and check FRU information when ordering hardware for expansion or replacement. For example, do so when changing the hardware configuration or replacing faulty hardware.
This section shows examples of the display by the commands used to check FRU information. For details on the individual commands, see the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 XSCF Reference Manual of the XCP firmware version used.
Checking the number of mounted FRUs
XSCF> showhardconf -u
SPARC M12-2S; Memory_Size:1024 GB; (*1)
+-----------------------------------+------------+
| FRU | Quantity |
+-----------------------------------+------------+
| BB | 1 | (*2)
| CMUL | 1 | (*3)
| Type:C | ( 1) |
| CPU | 1 |
| Freq:4.250 GHz; | ( 1) |
| MEM | 16 |
| Type:85; Size:32 GB; | ( 16) |
| CMUU | 1 |
| Type:C | ( 1) |
| CPU | 1 |
| Freq:4.250 GHz; | ( 1) |
| MEM | 16 |
| Type:85; Size:32 GB; | ( 16) |
| PCICARD | 0 |
| LINKCARD | 0 |
| PCIBOX | 0 |
| IOB | 0 |
| LINKBOARD | 0 |
| PCI | 0 |
| FANBP | 0 |
| PSU | 0 |
| FAN | 0 |
| XBU | 2 |
| Type:C | ( 2) |
| XSCFU | 1 |
| Type:A | ( 1) |
| OPNL | 1 |
| Type:A | ( 1) |
| PSUBP | 1 |
| Type:A | ( 1) |
| PSU | 4 |
| Type:C | ( 4) |
| FANU | 8 |
| HDDBP | 1 |
| XBBOX | 0 |
| XBU | 0 |
| XSCFU | 0 |
| OPNL | 0 |
| XBBPU | 0 |
| XSCFIFU | 0 |
| PSU | 0 |
| FANU | 0 |
+-----------------------------------+------------+
XSCF>
*1 Model information of the system and total capacity of the installed memory
*2 Number of SPARC M12-2/M12-2S units connected inside the system
*3 Number of CMUL units
Checking the FRU type
XSCF> showhardconf
SPARC M12-2S;
(Omitted)
BB#00 Status:Normal; Role:Master; Ver:3015h; Serial:PZ51649002;
(Omitted)
CMUL Status:Normal; Ver:2101h; Serial:PP164804GG ;
+ FRU-Part-Number:CA07855-D301 A5 /7341541 ;
+ Memory_Size:128 GB; Type: C ;
CPU#0 Status:Normal; Ver:4242h; Serial:00070051;
+ Freq:4.250 GHz; Type:0x30;
+ Core:12; Strand:8;
MEM#00A Status:Normal;
+ Code:ce8002M393A2K40BB1-CRC 00-31C04E6E;
+ Type:83; Size:16 GB;
(Omitted)
XSCF>
Table 8-2 lists combinations of the FRUs mounted in the SPARC M12 and FRU types.
Table 8-2  Combinations of Servers and FRU Types
Server Fujitsu Product ID (Oracle Product ID) FRU Type Indicator FRU Type Indicator
SPARC M12-2 SPNBBAA1xx (7117204) XSCFU A CMUL E
  SPNBBAA2xx (7602604)   A   C
  SPNBBAA3xx (7605162)   B   F
  SPNBBAA4xx (7605941)   C   G
SPARC M12-2S SPNCCAA1xx (7117206) XSCFU A CMUL E
  SPNCCAA2xx (7602605)   A   C
  SPNCCAA3xx (7605163)   B   F
  SPNCCAA4xx (7605942)   C   G
Table 8-3 shows the correspondence between memory mounted in the SPARC M12 and FRU types.
Table 8-3  Correspondence Between Memory and Types
FRU Type Indicator Configuration
Memory 81 DDR4 R-DIMM 8 GB 1 Rank
  83 DDR4 R-DIMM 16 GB 1 Rank
  85 DDR4 R-DIMM 32 GB 2 Rank
  87 DDR4 R-DIMM 64 GB 4 Rank
  91 DDR4 R-DIMM 64 GB 2 Rank
Note - The FRU type indicator may vary depending on the hardware configuration. See "Information on SPARC M12 System Hardware" in the Fujitsu SPARC M12 Product Notes for the latest XCP version.