8.1.6 Checking FRU Information
8.1.6 Checking FRU Information
FRU information includes detailed information on hardware. Log in to the XSCF shell and check FRU information when ordering hardware for expansion or replacement. For example, do so when changing the hardware configuration or replacing faulty hardware.
This section shows examples of the display by the commands used to check FRU information. For details on the individual commands, see the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 XSCF Reference Manual of the XCP firmware version used.
Checking the number of mounted FRUs
XSCF> showhardconf -u SPARC M12-2S; Memory_Size:1024 GB; (*1) +-----------------------------------+------------+ | FRU | Quantity | +-----------------------------------+------------+ | BB | 1 | (*2) | CMUL | 1 | (*3) | Type:C | ( 1) | | CPU | 1 | | Freq:4.250 GHz; | ( 1) | | MEM | 16 | | Type:85; Size:32 GB; | ( 16) | | CMUU | 1 | | Type:C | ( 1) | | CPU | 1 | | Freq:4.250 GHz; | ( 1) | | MEM | 16 | | Type:85; Size:32 GB; | ( 16) | | PCICARD | 0 | | LINKCARD | 0 | | PCIBOX | 0 | | IOB | 0 | | LINKBOARD | 0 | | PCI | 0 | | FANBP | 0 | | PSU | 0 | | FAN | 0 | | XBU | 2 | | Type:C | ( 2) | | XSCFU | 1 | | Type:A | ( 1) | | OPNL | 1 | | Type:A | ( 1) | | PSUBP | 1 | | Type:A | ( 1) | | PSU | 4 | | Type:C | ( 4) | | FANU | 8 | | HDDBP | 1 | | XBBOX | 0 | | XBU | 0 | | XSCFU | 0 | | OPNL | 0 | | XBBPU | 0 | | XSCFIFU | 0 | | PSU | 0 | | FANU | 0 | +-----------------------------------+------------+ XSCF> |
*1 Model information of the system and total capacity of the installed memory *2 Number of SPARC M12-2/M12-2S units connected inside the system *3 Number of CMUL units |
Checking the FRU type
XSCF> showhardconf SPARC M12-2S; (Omitted) BB#00 Status:Normal; Role:Master; Ver:3015h; Serial:PZ51649002; (Omitted) CMUL Status:Normal; Ver:2101h; Serial:PP164804GG ; + FRU-Part-Number:CA07855-D301 A5 /7341541 ; + Memory_Size:128 GB; Type: C ; CPU#0 Status:Normal; Ver:4242h; Serial:00070051; + Freq:4.250 GHz; Type:0x30; + Core:12; Strand:8; MEM#00A Status:Normal; + Code:ce8002M393A2K40BB1-CRC 00-31C04E6E; + Type:83; Size:16 GB; (Omitted) XSCF> |
Table 8-2 lists combinations of the FRUs mounted in the SPARC M12 and FRU types.
Server | Fujitsu Product ID (Oracle Product ID) | FRU | Type Indicator | FRU | Type Indicator |
---|---|---|---|---|---|
SPARC M12-2 | SPNBBAA1xx (7117204) | XSCFU | A | CMUL | E |
SPNBBAA2xx (7602604) | A | C | |||
SPNBBAA3xx (7605162) | B | F | |||
SPNBBAA4xx (7605941) | C | G | |||
SPARC M12-2S | SPNCCAA1xx (7117206) | XSCFU | A | CMUL | E |
SPNCCAA2xx (7602605) | A | C | |||
SPNCCAA3xx (7605163) | B | F | |||
SPNCCAA4xx (7605942) | C | G |
Table 8-3 shows the correspondence between memory mounted in the SPARC M12 and FRU types.
FRU | Type Indicator | Configuration |
---|---|---|
Memory | 81 | DDR4 R-DIMM 8 GB 1 Rank |
83 | DDR4 R-DIMM 16 GB 1 Rank | |
85 | DDR4 R-DIMM 32 GB 2 Rank | |
87 | DDR4 R-DIMM 64 GB 4 Rank | |
91 | DDR4 R-DIMM 64 GB 2 Rank |
Note - The FRU type indicator may vary depending on the hardware configuration. See "Information on SPARC M12 System Hardware" in the Fujitsu SPARC M12 Product Notes for the latest XCP version. |
< Previous Page | Next Page >