6.6.6 System-Stopped/Cold Removal Workflow of the SPARC M12-2S
6.6.6 System-Stopped/Cold Removal Workflow of the SPARC M12-2S
You can perform system-stopped/cold removal of the SPARC M12-2S in the following configuration:
- Multiple-BB configuration
Before removing the SPARC M12-2S, see "Precautions for SPARC M12-2S removal" in "7.3 Precautions for FRU Reduction."
Table 6-27 shows the workflow for system-stopped/cold removal of the SPARC M12-2S.
Work Order | Task | Reference |
---|---|---|
1 | Checking the operating condition of the system | "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains" |
2 | Checking the I/O device usage status of the SPARC M12-2S to be removed | "9.2.2 Checking the Assignment Status of I/O Devices" |
3 | Checking the HDD/SSD usage status of the SPARC M12-2S to be removed | "9.2.3 Checking the Usage of the HDD/SSD" |
4 | Powering off all physical partitions | "9.5.2 Stopping All Physical Partitions" |
5 | Switching the mode switch on the OPNL to Service | "2.3.2 OPNL Control Function" |
6 | Releasing the SPARC M12-2S to be removed, from the physical partition | "9.6.1 Releasing the SPARC M12-2S From the Building Block Configuration" |
7 | Releasing the SPARC M12-2S from the building block configuration | "9.7 Removing the SPARC M12-2S" |
8 | Diagnosing all the connected SPARC M12-2S units | "10.5.1 Diagnosing the SPARC M12 Hardware" |
9 | Confirming that there is no problem with the SPARC M12-2S released from the physical partition | "10.5.3 Checking the FRU Status After Maintenance" |
10 | Switching the mode switch on the OPNL to Locked | "2.3.2 OPNL Control Function" |
11 | Powering on all physical partitions | "10.9.1 Starting the System With an XSCF Command" |
12 | Checking the operating condition of the system (*2) | "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains" |
13 | Saving logical domain configuration information | "9.1.1 Saving Logical Domain Configuration Information" |
*1 If the removal of the SPARC M12-2S does not affect logical domains, this work is not required. *2 Reconfigure logical domains as required. For details, see "Chapter 3 Operations for Domain Configuration" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide. |