6.6.6 System-Stopped/Cold Removal Workflow of the SPARC M12-2S


6.6.6 System-Stopped/Cold Removal Workflow of the SPARC M12-2S
You can perform system-stopped/cold removal of the SPARC M12-2S in the following configuration:
  1. Multiple-BB configuration
Before removing the SPARC M12-2S, see "Precautions for SPARC M12-2S removal" in "7.3 Precautions for FRU Reduction."
Table 6-27 shows the workflow for system-stopped/cold removal of the SPARC M12-2S.
Table 6-27  System-Stopped/Cold Removal Procedure of the SPARC M12-2S
Work Order Task Reference
1 Checking the operating condition of the system "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
2 Checking the I/O device usage status of the SPARC M12-2S to be removed "9.2.2 Checking the Assignment Status of I/O Devices"
3 Checking the HDD/SSD usage status of the SPARC M12-2S to be removed "9.2.3 Checking the Usage of the HDD/SSD"
4 Powering off all physical partitions "9.5.2 Stopping All Physical Partitions"
5 Switching the mode switch on the OPNL to Service "2.3.2 OPNL Control Function"
6 Releasing the SPARC M12-2S to be removed, from the physical partition "9.6.1 Releasing the SPARC M12-2S From the Building Block Configuration"
7 Releasing the SPARC M12-2S from the building block configuration "9.7 Removing the SPARC M12-2S"
8 Diagnosing all the connected SPARC M12-2S units "10.5.1 Diagnosing the SPARC M12 Hardware"
9 Confirming that there is no problem with the SPARC M12-2S released from the physical partition "10.5.3 Checking the FRU Status After Maintenance"
10 Switching the mode switch on the OPNL to Locked "2.3.2 OPNL Control Function"
11 Powering on all physical partitions "10.9.1 Starting the System With an XSCF Command"
12 Checking the operating condition of the system (*2) "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
13 Saving logical domain configuration information "9.1.1 Saving Logical Domain Configuration Information"
*1 If the removal of the SPARC M12-2S does not affect logical domains, this work is not required.
*2 Reconfigure logical domains as required. For details, see "Chapter 3 Operations for Domain Configuration" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide.