10.5.2 Diagnosing the XBU and Crossbar Cable
10.5.2 Diagnosing the XBU and Crossbar Cable
This section describes the procedure for diagnosing the XBU and crossbar cable in a building block configuration.
<Description of options>
-b: Specify the BB-ID of the released SPARC M12-2S (communication source).
-t: Specify the BB-ID of the released SPARC M12-2S (communication destination).
-p: Specify the PPAR-ID (communication destination).
(1) Communication destination PPAR is running (active addition)
The following execution example diagnoses the XBU and crossbar cable between the SPARC M12-2S of BB#1 and the SPARC M12-2S operating in PPAR#0.
XSCF> diagxbu -y -b 01 -p 0 XBU diagnosis is about to start, Continue?[y|n] :y Power on sequence started. [7200sec] 0..... 30..... 60..... 90..end XBU diagnosis started. [7200sec] 0..... 30..... 60..... 90.....120.....150.....180.....210.....240.....| 270.....300.....330.....360.....390.....420...end completed. Power off sequence started. [1200sec] 0..... 30..... 60..... 90.....120end completed. *Note* Please confirm the error of XBU by "showlogs error". In addition, please confirm the degraded of XBU by "showstatus". |
(2) Incorporation destination PPAR is stopped (inactive addition)
The following execution example diagnoses the XBU and crossbar cable between the SPARC M12-2S of BB#3 and the SPARC M12-2S of BB#1 and BB#2 contained in PPAR#1, which is the incorporation destination.
XSCF> showpcl -p 1 PPAR-ID LSB PSB Status 01 Powered Off 00 01-0 01 02-0 XSCF> diagxbu -y -b 03 -t 01 -t 02 XBU diagnosis is about to start, Continue?[y|n] :y Power on sequence started. [7200sec] 0..... 30..... 60..... 90.....120end XBU diagnosis started. [7200sec] 0..... 30..... 60..... 90.....120end completed. Power off sequence started. [1200sec] 0..... 30..... 60..... 90.....120end completed. *Note* Please confirm the error of XBU by "showlogs error". In addition, please confirm the degraded of XBU by "showstatus". |
The hardware diagnosis that is run during the execution of the replacefru command does not cover the crossbar cable. If you have released the SPARC M12-2S from the building block configuration by using the replacefru command, wait until the replacefru command ends, and then diagnose the crossbar cable by using the diagxbu command.