22.4 Installing the XSCF BB Control Cable


22.4 Installing the XSCF BB Control Cable
This section describes the procedure for installing the XSCF BB control cable.
  1. Affix labels to the XSCF BB control cable.
    Affix the labels filled out in step 2 of "22.3 Removing the XSCF BB Control Cable" to the XSCF BB control cable (Figure 22-6).
Figure 22-6  Label Affixing Positions on the XSCF BB Control Cable
Figure 22-6  Label Affixing Positions on the XSCF BB Control Cable
Note - Affix a label 5 cm (2 in.) away from the XSCF BB control cable connector.
  1. Connect the XSCF BB control cable.
Figure 22-7  Connecting the XSCF BB Control Cable
Figure 22-7  Connecting the XSCF BB Control Cable
  1. Place the server in the hot state.
    To perform maintenance after every SPARC M12-2S was placed in the cold state without using the maintenance menu, install the power cords of every SPARC M12-2S. For details on installing the power cord on the PSU, see "10.1.1 Installing a Power Cord."
Figure 22-8  Installing the Power Cord
Figure 22-8  Installing the Power Cord