Skip to main content
  1. Home >
  2. Products >
  3. Computing Products >
  4. Servers >
  5. Fujitsu SPARC servers >
  6. Downloads >
  7. User Manuals >
  8. Fujitsu SPARC M12-2/M12-2S Service Manual >
  9. 5.6.1 System-Stopped/Cold Addition Workflow of a PCIe Card

5.6.1 System-Stopped/Cold Addition Workflow of a PCIe Card


5.6.1 System-Stopped/Cold Addition Workflow of a PCIe Card
Table 5-22 shows the workflow for system-stopped/cold addition of a PCIe card.
Table 5-22  System-Stopped/Cold Addition Procedure of a PCIe Card
Work Order Task Reference
1 Powering off all physical partitions "9.5.2 Stopping All Physical Partitions"
2 Switching the mode switch on the OPNL to Service "2.3.2 OPNL Control Function"
3 Removing the power cords of all the SPARC M12-2/M12-2S units "9.8.2 Removing the Power Cords"
4 Removing the PCICS from the SPARC M12-2/M12-2S "12.3.1 Enabling the Removal of a PCIe Card"
5 Removing the PCIe card filler from the PCICS "12.3.2 Removing a PCIe Card or PCIe Card Filler"
6 Installing a PCIe card in the PCICS to install it in the SPARC M12-2/M12-2S "12.4.1 Installing a PCIe Card or PCIe Card Filler"
7 Connecting the power cords of all the SPARC M12-2/M12-2S units "10.1.1 Installing a Power Cord"
8 Diagnosing the SPARC M12-2/M12-2S with the added PCIe card "10.5.1 Diagnosing the SPARC M12 Hardware"
9 Confirming that there is no problem with the added PCIe card "10.5.3 Checking the FRU Status After Maintenance"
10 Switching the mode switch on the OPNL to Locked "2.3.2 OPNL Control Function"
11 Powering on all physical partitions "10.9.1 Starting the System With an XSCF Command"
12 Assigning the I/O resource to a logical domain "3.2 Operations and Commands Related to Logical Domain Configurations" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide