Skip to main content
  1. Home >
  2. Products >
  3. Computing Products >
  4. Servers >
  5. Fujitsu SPARC servers >
  6. Downloads >
  7. User Manuals >
  8. Fujitsu SPARC M12-2/M12-2S Service Manual >
  9. 5.4.6 Inactive/Cold Addition Workflow of the SPARC M12-2S

5.4.6 Inactive/Cold Addition Workflow of the SPARC M12-2S


5.4.6 Inactive/Cold Addition Workflow of the SPARC M12-2S
You can perform inactive/cold addition of the SPARC M12-2S in the following model:
  1. One or more SPARC M12-2S units
Before adding the SPARC M12-2S, see "Precautions for SPARC M12-2S addition" in "7.2 Precautions for FRU Expansion." To mount the SPARC M12-2S to be added in a rack, see "3.4.1 Mounting the SPARC M12-2S in a Rack" in the Fujitsu SPARC M12-2S Installation Guide.
Table 5-18 shows the workflow for inactive/cold addition of the SPARC M12-2S.
Table 5-18  Inactive/Cold Addition Procedure of the SPARC M12-2S
Work Order Task Reference
1 Checking the operating condition of the system "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
2 Powering off the physical partition into which to incorporate the added SPARC M12-2S "9.5.1 Stopping a Specific Physical Partition"
3 Connecting the added SPARC M12-2S "3.4.1 Mounting the SPARC M12-2S in a Rack" in the Fujitsu SPARC M12-2S Installation Guide
4 Switching the mode switch on the OPNL to Service "2.3.2 OPNL Control Function"
5 Incorporating the SPARC M12-2S into a building block configuration (*1) "10.3 Adding the SPARC M12-2S to a Building Block Configuration"
6 Diagnosing the crossbar cable "10.5.2 Diagnosing the XBU and Crossbar Cable"
7 Confirming that there is no problem with the added SPARC M12-2S "10.5.3 Checking the FRU Status After Maintenance"
8 Configuring memory mirroring if duplicating memory "7.6 Configuring Memory Mirroring" in the Fujitsu SPARC M12-2S Installation Guide
9 Adding the added SPARC M12-2S to the PPAR configuration list for the physical partition that is the incorporation destination "7.7 Creating a PPAR Configuration List" in the Fujitsu SPARC M12-2S Installation Guide
10 Assigning the SPARC M12-2S (system board‌) to the physical partition "7.8.1 Assigning a Physical System Board (PSB) to a Physical Partition (PPAR)" in the Fujitsu SPARC M12-2S Installation Guide
11 Switching the mode switch on the OPNL to Locked "2.3.2 OPNL Control Function"
12 Powering on the physical partition of the added SPARC M12-2S "10.9.1 Starting the System With an XSCF Command"
13 Assigning the resources of the added SPARC M12-2S to logical domains "3.2 Operations and Commands Related to Logical Domain Configurations" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide
*1 Connect cables by following the workflow of the addfru command.