5.4.6 Inactive/Cold Addition Workflow of the SPARC M12-2S
5.4.6 Inactive/Cold Addition Workflow of the SPARC M12-2S
You can perform inactive/cold addition of the SPARC M12-2S in the following model:
- One or more SPARC M12-2S units
Before adding the SPARC M12-2S, see "Precautions for SPARC M12-2S addition" in "7.2 Precautions for FRU Expansion." To mount the SPARC M12-2S to be added in a rack, see "3.4.1 Mounting the SPARC M12-2S in a Rack" in the Fujitsu SPARC M12-2S Installation Guide.
Table 5-18 shows the workflow for inactive/cold addition of the SPARC M12-2S.
Work Order | Task | Reference |
---|---|---|
1 | Checking the operating condition of the system | "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains" |
2 | Powering off the physical partition into which to incorporate the added SPARC M12-2S | "9.5.1 Stopping a Specific Physical Partition" |
3 | Connecting the added SPARC M12-2S | "3.4.1 Mounting the SPARC M12-2S in a Rack" in the Fujitsu SPARC M12-2S Installation Guide |
4 | Switching the mode switch on the OPNL to Service | "2.3.2 OPNL Control Function" |
5 | Incorporating the SPARC M12-2S into a building block configuration (*1) | "10.3 Adding the SPARC M12-2S to a Building Block Configuration" |
6 | Diagnosing the crossbar cable | "10.5.2 Diagnosing the XBU and Crossbar Cable" |
7 | Confirming that there is no problem with the added SPARC M12-2S | "10.5.3 Checking the FRU Status After Maintenance" |
8 | Configuring memory mirroring if duplicating memory | "7.6 Configuring Memory Mirroring" in the Fujitsu SPARC M12-2S Installation Guide |
9 | Adding the added SPARC M12-2S to the PPAR configuration list for the physical partition that is the incorporation destination | "7.7 Creating a PPAR Configuration List" in the Fujitsu SPARC M12-2S Installation Guide |
10 | Assigning the SPARC M12-2S (system board) to the physical partition | "7.8.1 Assigning a Physical System Board (PSB) to a Physical Partition (PPAR)" in the Fujitsu SPARC M12-2S Installation Guide |
11 | Switching the mode switch on the OPNL to Locked | "2.3.2 OPNL Control Function" |
12 | Powering on the physical partition of the added SPARC M12-2S | "10.9.1 Starting the System With an XSCF Command" |
13 | Assigning the resources of the added SPARC M12-2S to logical domains | "3.2 Operations and Commands Related to Logical Domain Configurations" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide |
*1 Connect cables by following the workflow of the addfru command. |