  9. 5.6.4 System-Stopped/Cold Addition Workflow of Memory

5.6.4 System-Stopped/Cold Addition Workflow of Memory


5.6.4 System-Stopped/Cold Addition Workflow of Memory
You can perform system-stopped/cold addition of memory in the following configuration:
  1. Configuration connecting two or more SPARC M12-2S units to a physical partition
Table 5-25 shows the workflow for system-stopped/cold addition of memory.
Table 5-25  System-Stopped/Cold Addition Procedure of Memory
Work Order Task Reference
1 Powering off all physical partitions "9.5.2 Stopping All Physical Partitions"
2 Switching the mode switch on the OPNL to Service "2.3.2 OPNL Control Function"
3 Removing the power cords of all the SPARC M12-2S units "9.8.2 Removing the Power Cords"
4 Removing the CMU from the SPARC M12-2S "17.4 Removing the CMU or Memory"
5 Installing memory in the CMU and installing this unit in the SPARC M12-2S "17.5 Installing the CMU and Memory"
6 Connecting the power cords of all the SPARC M12-2S units "10.1.1 Installing a Power Cord"
7 Diagnosing all the SPARC M12-2S units "10.5.1 Diagnosing the SPARC M12 Hardware"
8 Confirming that there is no problem with the added memory "10.5.3 Checking the FRU Status After Maintenance"
9 Switching the mode switch on the OPNL to Locked "2.3.2 OPNL Control Function"
10 Powering on all physical partitions "10.9.1 Starting the System With an XSCF Command"
11 Assigning the resources of the expanded memory to logical domains "3.2 Operations and Commands Related to Logical Domain Configurations" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide