  8. Fujitsu SPARC M12-2/M12-2S Service Manual >
  9. 4.2.13 Active/Cold Replacement Workflow of the PCI Expansion Unit

4.2.13 Active/Cold Replacement Workflow of the PCI Expansion Unit


4.2.13 Active/Cold Replacement Workflow of the PCI Expansion Unit
You can perform active/cold replacement of a PCI expansion unit in the following configuration:
  1. Configuration connecting two or more SPARC M12-2S units to a physical partition
Table 4-20 shows the workflow for active/cold replacement of a PCI expansion unit.
Table 4-20 describes the procedure for replacing a FRU while the power cords of the PCI expansion unit are disconnected.
For replacement procedures for FRUs while the power cords of the PCI expansion unit are connected, see "7.1.1 Hot Replacement" in the PCI Expansion Unit for Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Service Manual.
Table 4-20  Active/Cold Replacement Procedure of a PCI Expansion Unit
Work Order Task Reference
1 Checking the operating condition of the system and the I/O device usage status "9.2 Checking the Operation Status and Resource Usage Status of Oracle Solaris"
2 Checking the logical domain assignment status of CPU resources mounted in the SPARC M12-2S requiring maintenance "3.2.4 Checking the Assignment Status of Resources" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide
3 Checking the logical domain assignment status of memory resources mounted in the SPARC M12-2S requiring maintenance "3.2.4 Checking the Assignment Status of Resources" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide
4 Releasing I/O resources of the SPARC M12-2S requiring maintenance from a logical domain "9.3 Releasing I/O Resources From a Logical Domain"
5 Releasing the SPARC M12-2S requiring maintenance from the physical partition "9.4.3 Dynamically Releasing the SPARC M12-2S From the Physical Partition"
6 Releasing the SPARC M12-2S requiring maintenance from the building block configuration "9.6.1 Releasing the SPARC M12-2S From the Building Block Configuration"
7 Placing the SPARC M12-2S requiring maintenance into the cold state "9.8.2 Removing the Power Cords"
8 Removing the FRUs in the faulty PCI expansion unit PCI Expansion Unit for Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Service Manual
9 Installing a FRU in the PCI expansion unit PCI Expansion Unit for Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Service Manual
10 Placing the SPARC M12-2S that required maintenance into the hot state "10.1.1 Installing a Power Cord"
11 Incorporating the SPARC M12-2S that required maintenance into the building block configuration "10.4.1 Incorporating the SPARC M12-2S Into a Building Block Configuration"
12 Diagnosing the SPARC M12-2S requiring maintenance "10.5.1 Diagnosing the SPARC M12 Hardware"
13 Confirming that there is no problem with the replacement PCI expansion unit "10.5.3 Checking the FRU Status After Maintenance"
14 Incorporating the SPARC M12-2S that required maintenance into the physical partition (*1) "10.6.1 Incorporating the SPARC M12-2S Into the Physical Partition Using PPAR DR"
15 Incorporating I/O resources of the SPARC M12-2S requiring maintenance into a logical domain "10.7 Incorporating I/O Resources Into a Logical Domain"
16 Checking the operating condition of the system and the I/O device usage status "9.2 Checking the Operation Status and Resource Usage Status of Oracle Solaris"
*1 Remove all the PCIe cards mounted in the PCI expansion unit when incorporating the SPARC M12-2S into the physical partition.