  9. 5.1.3 Active/Hot Addition Workflow of the PCI Expansion Unit

5.1.3 Active/Hot Addition Workflow of the PCI Expansion Unit


5.1.3 Active/Hot Addition Workflow of the PCI Expansion Unit
Before adding the PCI expansion unit, mount it in the rack. (See "3.3 Mounting the SPARC M12-2 and the PCI Expansion Unit in a Rack" in the Fujitsu SPARC M12-2 Installation Guide or "3.4 Mounting the SPARC M12-2S and the PCI Expansion Unit in a Rack" in the Fujitsu SPARC M12-2S Installation Guide.)
Table 5-3 shows the workflow for active/hot addition of the PCI expansion unit.
Table 5-3  Active/Hot Addition Procedure of a PCI Expansion Unit
Work Order Task Reference
1 Checking the operating condition of the system "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
2 Switching the mode switch on the OPNL to Service "2.3.2 OPNL Control Function"
3 Removing the PCICS from the SPARC M12-2/M12-2S "12.3.1 Enabling the Removal of a PCIe Card"
4 Removing the PCIe card filler from the PCICS "12.3.2 Removing a PCIe Card or PCIe Card Filler"
5 Installing the link card in the PCICS "12.4.1 Installing a PCIe Card or PCIe Card Filler"
6 Installing the link card in the SPARC M12-2/M12-2S "12.4.2 Incorporating a PCIe Card Into the System"
7 Connecting a PCI expansion unit to the link card "4.2 Connecting Cables to the PCI Expansion Unit" in the Fujitsu SPARC M12-2 Installation Guide
or
"5.2 Connecting Cables to the PCI Expansion Unit" in the Fujitsu SPARC M12-2S Installation Guide
8 Incorporating the added PCI expansion unit into the system (*1) "10.6.2 Incorporating an I/O Device Into the Physical Partition by Using the Hot Plug Function"
9 Confirming that there is no problem with the added PCI expansion unit "10.5.3 Checking the FRU Status After Maintenance"
10 Installing all the PCIe cards to be mounted in the PCI expansion unit "8.4 Installing a PCI Express Card" in the PCI Expansion Unit for Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Service Manual
11 Incorporating all the PCIe cards installed in the PCI expansion unit into the system "10.6.2 Incorporating an I/O Device Into the Physical Partition by Using the Hot Plug Function"
12 Confirming that there is no problem with the added PCI expansion unit "10.5.3 Checking the FRU Status After Maintenance"
13 Switching the mode switch on the OPNL to Locked "2.3.2 OPNL Control Function"
14 Assigning the I/O resource to a logical domain "3.2 Operations and Commands Related to Logical Domain Configurations" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide
*1 The direct I/O function needs to be disabled. Do not mount any PCIe card in the PCI expansion unit during active addition of the PCI expansion unit.