6.6.5 System-Stopped/Cold Removal Workflow of the PCI Expansion Unit


6.6.5 System-Stopped/Cold Removal Workflow of the PCI Expansion Unit
Table 6-26 shows the workflow for system-stopped/cold removal of a PCI expansion unit.
Table 6-26  System-Stopped/Cold Removal Procedure of a PCI Expansion Unit
Work Order Task Reference
1 Checking the operating condition of the system "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
2 Releasing the assignment of the I/O resources of the PCIe cards mounted in the PCI expansion unit to be removed "9.3 Releasing I/O Resources From a Logical Domain"
3 Confirming that you can remove the PCIe cards mounted in the PCI expansion unit to be removed (*1) "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
4 Saving logical domain configuration information "9.1.1 Saving Logical Domain Configuration Information"
5 Powering off all physical partitions "9.5.2 Stopping All Physical Partitions"
6 Switching the mode switch on the OPNL to Service "2.3.2 OPNL Control Function"
7 Removing the power cords of all the SPARC M12-2/M12-2S units "9.8.2 Removing the Power Cords"
8 Releasing the PCI expansion unit to be removed and the link card PCI Expansion Unit for Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Service Manual
9 Removing the PCICS in which the link card is mounted from the SPARC M12-2/M12-2S "12.3.1 Enabling the Removal of a PCIe Card"
10 Removing the link card from the PCICS "12.3.2 Removing a PCIe Card or PCIe Card Filler"
11 Installing a PCIe card filler in the PCICS, and installing the PCICS in the SPARC M12-2/M12-2S "12.4.1 Installing a PCIe Card or PCIe Card Filler"
12 Installing the power cords of all the SPARC M12-2/M12-2S units "10.1.1 Installing a Power Cord"
13 Powering on all physical partitions "10.9.1 Starting the System With an XSCF Command"
14 Confirming that there is no problem with the system from which the PCI expansion unit was removed "10.5.3 Checking the FRU Status After Maintenance"
15 Switching the mode switch on the OPNL to Locked "2.3.2 OPNL Control Function"
16 Checking the operating condition of the physical partition and logical domains (*1) "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
17 Saving logical domain configuration information "9.1.1 Saving Logical Domain Configuration Information"
*1 Reconfigure logical domains as required. For details, see "Chapter 5 Logical Domain Configuration Example" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide.