Skip to main content
  1. Home >
  2. Products >
  3. Computing Products >
  4. Servers >
  5. Fujitsu SPARC servers >
  6. Downloads >
  7. User Manuals >
  8. Fujitsu SPARC M12-2/M12-2S Service Manual >
  9. 6.4.2 Inactive/Cold Removal Workflow of the HDD/SSD

6.4.2 Inactive/Cold Removal Workflow of the HDD/SSD


6.4.2 Inactive/Cold Removal Workflow of the HDD/SSD
You can perform inactive/cold removal of the HDD/SSD in the following configuration:
  1. Configuration connecting two or more SPARC M12-2S units to a physical partition
Before removing the HDD/SSD, see "Precautions for HDD/SSD removal" in "7.3 Precautions for FRU Reduction."
Table 6-14 shows the workflow for inactive/cold removal of the HDD/SSD.
Table 6-14  Inactive/Cold Removal Procedure of the HDD/SSD
Work Order Task Reference
1 Checking the operating condition of the system "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
2 Releasing the assignment of the I/O resources of the HDD/SSD to be removed "9.3 Releasing I/O Resources From a Logical Domain"
3 Confirming that you can remove the HDD/SSD to be removed (*1) "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
4 Saving logical domain configuration information "9.1.1 Saving Logical Domain Configuration Information"
5 Powering off the physical partition containing the SPARC M12-2S that houses the HDD/SSD to be removed "9.5.1 Stopping a Specific Physical Partition"
6 Switching the mode switch on the OPNL to Service "2.3.2 OPNL Control Function"
7 Releasing the SPARC M12-2S that houses the HDD/SSD to be removed, from the building block configuration "9.6.1 Releasing the SPARC M12-2S From the Building Block Configuration"
8 Removing the HDD/SSD to be removed from the SPARC M12-2S "15.3.1 Removing an HDD/SSD"
9 Installing a filler unit in the SPARC M12-2S "15.4.2 Installing a Filler Unit"
10 Incorporating the SPARC M12-2S from which the HDD/SSD was removed into the building block configuration "10.4.1 Incorporating the SPARC M12-2S Into a Building Block Configuration"
11 Powering on the physical partition containing the SPARC M12-2S that underwent maintenance "10.9.1 Starting the System With an XSCF Command"
12 Confirming that there is no problem with the system from which the HDD/SSD was removed "10.5.3 Checking the FRU Status After Maintenance"
13 Switching the mode switch on the OPNL to Locked "2.3.2 OPNL Control Function"
14 Checking the operating condition of the physical partition and logical domains (*1) "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
15 Saving logical domain configuration information "9.1.1 Saving Logical Domain Configuration Information"
*1 Reconfigure logical domains as required. For details, see "Chapter 3 Operations for Domain Configuration" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide. If you have reconfigured a logical domain, save the logical domain configuration information.