6.4.2 Inactive/Cold Removal Workflow of the HDD/SSD
6.4.2 Inactive/Cold Removal Workflow of the HDD/SSD
You can perform inactive/cold removal of the HDD/SSD in the following configuration:
- Configuration connecting two or more SPARC M12-2S units to a physical partition
Before removing the HDD/SSD, see "Precautions for HDD/SSD removal" in "7.3 Precautions for FRU Reduction."
Table 6-14 shows the workflow for inactive/cold removal of the HDD/SSD.
Work Order | Task | Reference |
---|---|---|
1 | Checking the operating condition of the system | "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains" |
2 | Releasing the assignment of the I/O resources of the HDD/SSD to be removed | "9.3 Releasing I/O Resources From a Logical Domain" |
3 | Confirming that you can remove the HDD/SSD to be removed (*1) | "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains" |
4 | Saving logical domain configuration information | "9.1.1 Saving Logical Domain Configuration Information" |
5 | Powering off the physical partition containing the SPARC M12-2S that houses the HDD/SSD to be removed | "9.5.1 Stopping a Specific Physical Partition" |
6 | Switching the mode switch on the OPNL to Service | "2.3.2 OPNL Control Function" |
7 | Releasing the SPARC M12-2S that houses the HDD/SSD to be removed, from the building block configuration | "9.6.1 Releasing the SPARC M12-2S From the Building Block Configuration" |
8 | Removing the HDD/SSD to be removed from the SPARC M12-2S | "15.3.1 Removing an HDD/SSD" |
9 | Installing a filler unit in the SPARC M12-2S | "15.4.2 Installing a Filler Unit" |
10 | Incorporating the SPARC M12-2S from which the HDD/SSD was removed into the building block configuration | "10.4.1 Incorporating the SPARC M12-2S Into a Building Block Configuration" |
11 | Powering on the physical partition containing the SPARC M12-2S that underwent maintenance | "10.9.1 Starting the System With an XSCF Command" |
12 | Confirming that there is no problem with the system from which the HDD/SSD was removed | "10.5.3 Checking the FRU Status After Maintenance" |
13 | Switching the mode switch on the OPNL to Locked | "2.3.2 OPNL Control Function" |
14 | Checking the operating condition of the physical partition and logical domains (*1) | "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains" |
15 | Saving logical domain configuration information | "9.1.1 Saving Logical Domain Configuration Information" |
*1 Reconfigure logical domains as required. For details, see "Chapter 3 Operations for Domain Configuration" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide. If you have reconfigured a logical domain, save the logical domain configuration information. |