Skip to main content

10.5.1 Diagnosing the SPARC M12 Hardware


10.5.1 Diagnosing the SPARC M12 Hardware
This section describes the procedure for performing a hardware diagnosis on the SPARC M12.
If the CMUL has been replaced, confirm that the combination of the CMUL and XSCFU types is correct by using the showhardconf command, before performing step (1) or (2) below. For details, see Table 8-2 in "8.1.6  Checking FRU Information."
Select either step (1) or (2) below to perform a hardware diagnosis on the SPARC M12 with the testsb command.
(1)  Diagnosing the SPARC M12 by specifying its PSB
(2)  Diagnosing all the SPARC M12 units
For a configuration with only one SPARC M12-2 or SPARC M12-2S, either of steps (1) and (2) can be selected for the diagnosis.
<‌Description of options>‌
-v: Displays a detailed message on the hardware diagnosis.

-p: Displays the storage connected to the SPARC M12.

-s: Displays the device tree.

-a: Diagnoses all the mounted SPARC M12 units.
If you do not specify -a, you need to specify the PSB of the SPARC M12-2S to be diagnosed.
(1) Diagnosing the SPARC M12 by specifying its PSB
The following example runs the hardware diagnosis on the SPARC M12-2S with PSB 01-0 and checks the I/O connections.
XSCF> testsb -v -p -s -y 01-0
Initial diagnosis is about to start, Continue?[y|n] :y
PSB#01-0 power on sequence started.
:
(Omitted)
:
/pci@8500/pci@4/pci@0/pci@0/scsi@0
FCode Version 1.00.56, MPT Version 2.00, Firmware Version 20.00.10.00
Target a
Unit 0 Encl Serv device FUJITSU BBEXP 1303
SASAddress 500000e0e0b0117d PhyNum 14
/pci@8100/pci@4/pci@0/pci@0/scsi@0
FCode Version 1.00.56, MPT Version 2.00, Firmware Version 20.00.10.00
Target a
Unit 0 Disk TOSHIBA AL13SEB600 3703 1172123568 Blocks, 600 GB
SASDeviceName 50000396f8120578 SASAddress 50000396f812057a PhyNum 0
Target b
Unit 0 Disk TOSHIBA AL13SEB600 3703 1172123568 Blocks, 600 GB
SASDeviceName 50000396f8120498 SASAddress 50000396f812049a PhyNum 1
Target c
Unit 0 Encl Serv device FUJITSU BBEXP 1303
SASAddress 500000e0e0b0117d PhyNum 14
:
(Omitted)
:
/pci@8700/pci@4
/pci@8700/pci@4/pci@0
/pci@8700/pci@4/pci@0/pci@10
/pci@8600/pci@4
/pci@8600/pci@4/pci@0
/pci@8600/pci@4/pci@0/pci@10
/pci@8600/pci@4/pci@0/pci@1
/pci@8500/pci@4
/pci@8500/pci@4/pci@0
/pci@8500/pci@4/pci@0/pci@1
/pci@8500/pci@4/pci@0/pci@0
/pci@8500/pci@4/pci@0/pci@0/scsi@0
/pci@8500/pci@4/pci@0/pci@0/scsi@0/disk
/pci@8500/pci@4/pci@0/pci@0/scsi@0/tape
/pci@8400/pci@4
/pci@8400/pci@4/pci@0
/pci@8400/pci@4/pci@0/pci@1
/pci@8400/pci@4/pci@0/pci@0
/pci@8400/pci@4/pci@0/pci@0/network@0,1
/pci@8400/pci@4/pci@0/pci@0/network@0
:
(Omitted)
:
{0} ok
PSB power off sequence started. [1200sec]
0..... 30..... 60..end

PSB powered off.
PSB Test Fault
---- ------- --------

01-0 Passed Normal
XSCF> 
(2) Diagnosing all the SPARC M12 units
The following example runs the hardware diagnosis on all the connected SPARC M12 units and checks the I/O connections.
XSCF> testsb -v -p -s -a -y
Initial diagnosis is about to start, Continue?[y|n] :y
PSB power on sequence started.
    :
  (Omitted)
    :
/pci@8500/pci@4/pci@0/pci@0/scsi@0
FCode Version 1.00.56, MPT Version 2.00, Firmware Version 20.00.07.00
Target a
  Unit 0   Encl Serv device   FUJITSU  BBEXP            1303
  SASAddress 500000e0e0b0103d  PhyNum 14
/pci@8100/pci@4/pci@0/pci@0/scsi@0
FCode Version 1.00.56, MPT Version 2.00, Firmware Version 20.00.07.00
Target a
  Unit 0   Disk   TOSHIBA  AL13SEB600AL14SE 3702 1172123568   Blocks, 600 GB
  SASDeviceName 50000397682141a1  SASAddress 50000397682141a2 PhyNum 0
Target b
  Unit 0   Disk   TOSHIBA  AL13SEB600AL14SE 3702 1172123568   Blocks, 600 GB
  SASDeviceName 5000039768215115  SASAddress 5000039768215116 PhyNum 1
Target c
  Unit 0   Encl Serv device   FUJITSU  BBEXP            1303
  SASAddress 500000e0e0b0103d  PhyNum 14
    :
  (Omitted)
    :
/pci@8700/pci@4
/pci@8700/pci@4/pci@0
/pci@8700/pci@4/pci@0/pci@10
/pci@8600/pci@4
/pci@8600/pci@4/pci@0
/pci@8600/pci@4/pci@0/pci@10
/pci@8600/pci@4/pci@0/pci@1
/pci@8600/pci@4/pci@0/pci@10/pci@0
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0/pci@0
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0/pci@0/pci@1
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0/pci@0/pci@1/pci@0
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0/pci@0/pci@1/pci@0/pci@11
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0/pci@0/pci@1/pci@0/pci@10
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0/pci@0/pci@1/pci@0/pci@8
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0/pci@0/pci@1/pci@0/pci@1
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0/pci@0/pci@1/pci@0/pci@0
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0/pci@0/pci@1/pci@0/pci@11/pci@0
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0/pci@0/pci@1/pci@0/pci@11/pci@0/pci@11
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0/pci@0/pci@1/pci@0/pci@11/pci@0/pci@10
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0/pci@0/pci@1/pci@0/pci@11/pci@0/pci@1
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0/pci@0/pci@1/pci@0/pci@11/pci@0/pci@0
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0/pci@0/pci@1/pci@0/pci@10/pci@0
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0/pci@0/pci@1/pci@0/pci@10/pci@0/pci@11
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0/pci@0/pci@1/pci@0/pci@10/pci@0/pci@10
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0/pci@0/pci@1/pci@0/pci@10/pci@0/pci@1
/pci@8600/pci@4/pci@0/pci@10/pci@0/pci@0/pci@0/pci@1/pci@0/pci@10/pci@0/pci@0
    :
  (Omitted)
    :
{0} ok
--------------------------------------------------------------------------------

[PCIBOX Versions]
  PCIBOX                        Ver         Link                          Ver
      Info
  PCIBOX#1001                   1307        BB#00-PCI#03                  1307
      equal
--------------------------------------------------------------------------------

[PCIBOX Informations]
Location                      Type       FW Ver       Serial Num        Part Num
                                    State
PCIBOX#1001                   PCIBOX     -            2121231001
                                    On
PCIBOX#1001/PSU#0             PSU        -            FEJD1212000616
CA01022-0750-D/                             On
PCIBOX#1001/PSU#1             PSU        -            FEJD1212000621
CA01022-0750-D/                             On
PCIBOX#1001/IOB               IOBOARD    1310         PP123701KU
CA20365-B66X 009AH                          On
PCIBOX#1001/LINKBD            BOARD      -            PP140801ZC
CA20365-B60X 009AD/7061035                  On
PCIBOX#1001/FANBP             FANBP      -            PP1229015U
CA20365-B68X 004AC                          On
BB#00-PCI#03                  CARD       1310         PP13490468
CA20365-B59X 012AD/9999999                  On
--------------------------------------------------------------------------------

PSB power off sequence started. [1200sec]
  0..... 30..... 60..end
PSB powered off.
PSB Test Fault
---- ------- --------

00-0 Passed Normal