You can perform inactive/hot addition of the HDD/SSD in the following configuration:
  1. Building block configuration where two or more physical partitions are operating
Table 5-11 shows the workflow for inactive/hot addition of the HDD/SSD.
Table 5-11  Inactive/Hot Addition Procedure of the HDD/SSD
Work Order Task Reference
1 Checking the operating condition of the system "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
2 Powering off the physical partition containing the SPARC M12-2S to which to add the HDD/SSD "9.5.1 Stopping a Specific Physical Partition"
3 Switching the mode switch on the OPNL to Service "2.3.2 OPNL Control Function"
4 Removing the filler unit from the SPARC M12-2S "15.3.2 Removing a Filler Unit"
5 Installing an HDD/SSD in the SPARC M12-2S "15.4.1 Installing an HDD/SSD"
6 Diagnosing the SPARC M12-2S that has undergone maintenance "10.5.1 Diagnosing the SPARC M12 Hardware"
7 Confirming that there is no problem with the added HDD/SSD "10.5.3 Checking the FRU Status After Maintenance"
8 Switching the mode switch on the OPNL to Locked "2.3.2 OPNL Control Function"
9 Powering on the physical partition containing the SPARC M12-2S that underwent maintenance "10.9.1 Starting the System With an XSCF Command"
10 Assigning the I/O resource to a logical domain "3.2 Operations and Commands Related to Logical Domain Configurations" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide