  8. Fujitsu SPARC M12-2/M12-2S Service Manual >
  9. 3.2.3 Types of Maintenance for FRU Removal (SPARC M12-2)

3.2.3 Types of Maintenance for FRU Removal (SPARC M12-2)


3.2.3 Types of Maintenance for FRU Removal (SPARC M12-2)
Table 3-7 lists the FRUs that can be removed from the SPARC M12-2 and the applicable types of maintenance in the removal of each FRU.
Table 3-7  Applicable Types of Maintenance in FRU Removal from the SPARC M12-2
-: Not applicable
FRU Active Removal Inactive Removal System-Stopped Removal
Hot Cold Hot Cold Hot Cold
PCIe card OK - - - OK OK
HDD/SSD OK - - - OK OK
CMUU - - - - - OK
Memory - - - - - OK
PCI expansion unit (chassis) OK - - - OK OK
Active/Hot removal
Figure 3-7 shows the state of the system during active/hot removal in the SPARC M12-2.
Figure 3-7  Active/Hot Removal in the SPARC M12-2
Figure 3-7  Active/Hot Removal in the SPARC M12-2
System-Stopped/Hot removal
Figure 3-8 shows the state of the system during system-stopped/hot removal in the SPARC M12-2.
Figure 3-8  System-Stopped/Hot Removal in the SPARC M12-2
Figure 3-8  System-Stopped/Hot Removal in the SPARC M12-2
System-Stopped/Cold removal
Figure 3-9 shows the state of the system during system-stopped/cold removal in the SPARC M12-2.
Figure 3-9  System-Stopped/Cold Removal in the SPARC M12-2
Figure 3-9  System-Stopped/Cold Removal in the SPARC M12-2