  9. 10.4.1 Incorporating the SPARC M12-2S Into a Building Block Configuration

10.4.1 Incorporating the SPARC M12-2S Into a Building Block Configuration


10.4.1 Incorporating the SPARC M12-2S Into a Building Block Configuration
This section describes the procedure for incorporating the SPARC M12-2S that has undergone maintenance into a building block configuration. This procedure is done after the one described in "9.6.1 Releasing the SPARC M12-2S From the Building Block Configuration."
Note - This procedure assumes that the cables are connected to the SPARC M12-2S that has undergone maintenance and that the READY LED on the XSCFU is blinking.
  1. Incorporate the SPARC M12-2S.
    Return to the operation screen of the replacefru command of the XSCF shell, and enter "f".
Please execute the following steps:
1) Confirm the XSCF STANDBY LED of BB#0 is not lit.
2) Turn off the breaker of BB#0.
3) Remove BB#0.
4) Execute either the following:
4-1) After the exchanged device is connected with the system,
turn on the breaker of BB#0, and please select 'finish'.
4-2) If you want to suspend the maintenance without exchanging device,
please select 'cancel'.
[f:finish|c:cancel] :f
  1. The following screen appears when you enter "f". Wait for the processing to finish.
Waiting for BB#0 to enter install state.
[This operation may take up to 20 minute(s)]
(progress scale reported in seconds)
0..... 30..... 60..... 90..... 120..... 150..... 180..... 210.....
240..... 270..... 300..... 330..... 360..... done


Waiting for BB#0 to enter ready state.
[This operation may take up to 45 minute(s)]
(progress scale reported in seconds)
0..... 30..... 60..... 90..... 120..... 150..... 180..... 210.....
240..... 270..... 300..... done


Do you want to start to diagnose BB#0?[s:start|c:cancel] :
  1. Diagnose the hardware of the SPARC M12-2S that has undergone maintenance.
    When the following message appears, enter "s." If you cancel the diagnosis, Unknown will be displayed under Status in step 4.
Do you want to start to diagnose BB#0?[s:start|c:cancel] :s
Note - If the CMUL has been replaced, select "c" (cancel) in step 2 to end the replacefru command. Then, confirm that the combination of the CMUL and XSCFU types is correct by using the showhardconf command. After that, run a diagnosis with the testsb command. For details on the showhardconf and testsb commands, see "10.5.1 Diagnosing the SPARC M12 Hardware."
Note - The hardware diagnosis in step 2 does not cover PCIe cards, HDDs/SSDs, and PCI expansion units.
In the following cases, select "c" (cancel) in step 2 to end the replacefru command. Then, run a diagnosis with the testsb command. For details on the testsb command, see "10.5.1 Diagnosing the SPARC M12 Hardware."
- You have performed maintenance on a PCIe card, HDD/SSD, or PCI expansion unit with the SPARC M12-2S released.

- You have performed CMUU, memory, BPU, or PSUBP maintenance in the SPARC M12-2/M12-2S with a PCIe card mounted.
Note - For the XSCF DUAL control cable and the XSCF BB control cable, select "c" (cancel) in step 2.
  1. When the following message appears, check that the diagnosis target is BB#0 and then enter "y" to start the hardware diagnosis.
Diagnostic tests for BB#0 have started.
Initial diagnosis is about to start, Continue?[y|n] :y
  1. During the hardware diagnosis, the following is displayed to let you check the status of the diagnosis.
PSB#00-0 power on sequence started.
0....end
Initial diagnosis started. [7200sec]
0..... 30..... 60..... 90.....120.....150.....180.....210.....240...../
270.....300.....330.....360.....390.....420.....450.....480.....510.....-

540.end

Initial diagnosis has completed.
PSB power off sequence started. [1200sec]
0..... 30.....end
PSB powered off.
PSB Test Fault
---- ------- --------

00-0 Passed Normal
done
  1. Check the hardware diagnosis result.
    Check that Normal is displayed under Status. Then, enter "f" to finish the maintenance of the SPARC M12-2S.
------------------------------------------------------------------------------

Maintenance/Replacement Menu
Status of the replaced FRU.

FRU Status
------------------- --------------

/BB#0 Normal
------------------------------------------------------------------------------

The replacement of BB#0 has completed normally.[f:finish] :f
  1. If the displayed status is abnormal (Degrade or Fault), finish the maintenance of the SPARC M12-2S and return to the maintenance start screen. Perform maintenance on the SPARC M12-2S again, and check whether the replaced FRU is correctly mounted.
  1. End the replacefru command.
    When the maintenance start screen appears, enter "c" to end the replacefru command.
------------------------------------------------------------------------------

Maintenance/Replacement Menu
Please select the chassis including replaced FRU.
No. FRU Status
--- ------------------- --------------

1 /BB#0 Normal

2 /BB#1 Normal

3 /BB#2 Normal

4 /BB#3 Normal

------------------------------------------------------------------------------

Select [1-4|c:cancel] :c
XSCF>