  9. 6.4.6 Inactive/Cold Removal Workflow of the SPARC M12-2S

6.4.6 Inactive/Cold Removal Workflow of the SPARC M12-2S


6.4.6 Inactive/Cold Removal Workflow of the SPARC M12-2S
You can perform inactive/cold removal of the SPARC M12-2S in the following configuration:
  1. Building block configuration where two or more physical partitions are operating
Before removing the SPARC M12-2S, see "Precautions for SPARC M12-2S removal" in "7.3 Precautions for FRU Reduction."
Table 6-18 shows the workflow for inactive/cold removal of the SPARC M12-2S.
Table 6-18  Inactive/Cold Removal Procedure of the SPARC M12-2S
Work Order Task Reference
1 Checking the operating condition of the system "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
2 Checking the I/O device usage status of the SPARC M12-2S to be removed "9.2.2 Checking the Assignment Status of I/O Devices"
3 Checking the HDD/SSD usage status of the SPARC M12-2S to be removed "9.2.3 Checking the Usage of the HDD/SSD"
4 Powering off the physical partition containing the SPARC M12-2S to be removed "9.5.1 Stopping a Specific Physical Partition"
5 Switching the mode switch on the OPNL to Service "2.3.2 OPNL Control Function"
6 Releasing the SPARC M12-2S from the building block configuration (*3) "9.7 Removing the SPARC M12-2S"
7 Switching the mode switch on the OPNL to Locked "2.3.2 OPNL Control Function"
8 Powering on the physical partition of the system after releasing the SPARC M12-2S "10.9.1 Starting the System With an XSCF Command"
9 Checking the operating condition of the system after releasing the SPARC M12-2S (*2) "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
10 Saving logical domain configuration information "9.1.1 Saving Logical Domain Configuration Information"
*1 If the removal of the SPARC M12-2S does not affect logical domains, this work is not required.
*2 Reconfigure logical domains as required. For details, see "Chapter 3 Operations for Domain Configuration" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide.
*3 Set the physical partition definitions again as required.