Skip to main content

8.1.2 Checking Hardware


8.1.2 Checking Hardware
Log in to the XSCF shell or Oracle Solaris to check the hardware in the system configuration and the hardware RAID volumes.
Checking the SPARC M12-2/M12-2S
To check the system information of the SPARC M12-2/M12-2S and the FRUs mounted in it, log in to the XSCF shell and check the information displayed by the showhardconf command.
The showhardconf command displays the following SPARC M12-2/M12-2S information:
  1. Model
  2. System, server, and FRU serial numbers
  3. Information on the CPU, memory, and other hardware mounted in the SPARC M12-2/M12-2S
  4. System operation status
Be sure to check and make a note of the hardware configuration before you perform maintenance work.
The following example shows the information you get when you execute the showhardconf command in the SPARC M12-2S.
XSCF> showhardconf
SPARC M12-2S; (*1)
    + Serial:PZ51649002; Operator_Panel_Switch:Service; (*2)
    + System_Power:On; System_Phase:Cabinet Power On; (*3)
    Partition#0 PPAR_Status:Running;
    BB#00 Status:Normal; Role:Master; Ver:3015h; Serial:PZ51649002; (*4)
        + FRU-Part-Number:CA20369-B17X 005AC/7341758              ;
        + Power_Supply_System: ;
        + Memory_Size:256 GB;
        CMUL Status:Normal; Ver:2101h; Serial:PP164804GG  ; (*5)
            + FRU-Part-Number:CA07855-D301 A5   /7341541              ;
            + Memory_Size:128 GB; Type: C ;
            CPU#0 Status:Normal; Ver:4242h; Serial:00070051;
                + Freq:4.250 GHz; Type:0x30;
                + Core:12; Strand:8;
            MEM#00A Status:Normal;
                + Code:ce8002M393A2K40BB1-CRC    00-31C04E6E;
                + Type:83; Size:16 GB;
            MEM#01A Status:Normal;
                + Code:ce8002M393A2K40BB1-CRC    00-31C04ED1;
                + Type:83; Size:16 GB;
            MEM#02A Status:Normal;
                + Code:ce8002M393A2K40BB1-CRC    00-31C0510D;
                + Type:83; Size:16 GB;
            MEM#03A Status:Normal;
                + Code:ce8002M393A2K40BB1-CRC    00-31C04F51;
                + Type:83; Size:16 GB;
            MEM#04A Status:Normal;
                + Code:ce8002M393A2K40BB1-CRC    00-31C04E6F;
                + Type:83; Size:16 GB;
            MEM#05A Status:Normal;
                + Code:ce8002M393A2K40BB1-CRC    00-31C04F50;
                + Type:83; Size:16 GB;
            MEM#06A Status:Normal;
                + Code:ce8002M393A2K40BB1-CRC    00-31C04EFB;
                + Type:83; Size:16 GB;
            MEM#07A Status:Normal;
                + Code:ce8002M393A2K40BB1-CRC    00-31C051AE;
                + Type:83; Size:16 GB;
        CMUU Status:Normal; Ver:2101h; Serial:PP164804GN  ;
            + FRU-Part-Number:CA07855-D451 A4   /7341568              ;
            + Memory_Size:128 GB; Type: C ;
            CPU#0 Status:Normal; Ver:4242h; Serial:00070043;
                + Freq:4.250 GHz; Type:0x30;
                + Core:12; Strand:8;
            MEM#00A Status:Normal;
                + Code:ce8002M393A2K40BB1-CRC    00-31C04EF7;
                + Type:83; Size:16 GB;
            MEM#01A Status:Normal;
                + Code:ce8002M393A2K40BB1-CRC    00-31C051AB;
                + Type:83; Size:16 GB;
            MEM#02A Status:Normal;
                + Code:ce8002M393A2K40BB1-CRC    00-31C04EFD;
                + Type:83; Size:16 GB;
            MEM#03A Status:Normal;
                + Code:ce8002M393A2K40BB1-CRC    00-31C04ED2;
                + Type:83; Size:16 GB;
            MEM#04A Status:Normal;
                + Code:ce8002M393A2K40BB1-CRC    00-31C04EF6;
                + Type:83; Size:16 GB;
            MEM#05A Status:Normal;
                + Code:ce8002M393A2K40BB1-CRC    00-31C04F57;
                + Type:83; Size:16 GB;
            MEM#06A Status:Normal;
                + Code:ce8002M393A2K40BB1-CRC    00-31C04EAC;
                + Type:83; Size:16 GB;
            MEM#07A Status:Normal;
                + Code:ce8002M393A2K40BB1-CRC    00-31C04EA8;
                + Type:83; Size:16 GB;
        PCI#0 Name_Property:network; (*6)
            + Vendor-ID:8086; Device-ID:1521;
            + Subsystem_Vendor-ID:108e; Subsystem-ID:7b18;
            + Model:SUNW,pcie-igb;
        PCI#2 Name_Property:network;
            + Vendor-ID:8086; Device-ID:1528;
            + Subsystem_Vendor-ID:108e; Subsystem-ID:7b15;
            + Model:ATO:7070007, PTO:7070005;
        PCI#4 Name_Property:network;
            + Vendor-ID:8086; Device-ID:10fb;
            + Subsystem_Vendor-ID:108e; Subsystem-ID:7b11;
            + Model:X1109a-z/1109a-z;
        PCI#6 Name_Property:QLGC,qlc;
            + Vendor-ID:1077; Device-ID:2532;
            + Subsystem_Vendor-ID:1077; Subsystem-ID:015d;
            + Model:QLE2562 ;
        XBU#0 Status:Normal; Ver:1101h; Serial:PP164601DU  ;
            + FRU-Part-Number:CA20369-B18X 004AB/7341570              ;
            + Type: C ;
        XBU#1 Status:Normal; Ver:1101h; Serial:PP164601DV  ;
            + FRU-Part-Number:CA20369-B18X 004AB/7341570              ;
            + Type: C ;
        XSCFU Status:Normal; Ver:0101h; Serial:PP164603JA  ;
            + FRU-Part-Number:CA20369-B08X 006AC/7341765              ;
            + Type: A ;
        OPNL Status:Normal; Ver:0101h; Serial:PP164702EE  ;
            + FRU-Part-Number:CA20365-B35X 006AC/7060922              ;
            + Type: A ;
        PSUBP Status:Normal; Ver:1101h; Serial:PP164603HH  ;
            + FRU-Part-Number:CA20369-B17X 005AC/7341758              ;
            + Type: C ;
        PSU#0 Status:Normal; Ver:303242h; Serial:HWCD1622000551;
            + FRU-Part-Number:CA01022-0850/7334651      ;
            + Power_Status:ON; AC:200 V; Type: C ;
        PSU#1 Status:Normal; Ver:303242h; Serial:HWCD1622000586;
            + FRU-Part-Number:CA01022-0850/7334651      ;
            + Power_Status:ON; AC:200 V; Type: C ;
        PSU#2 Status:Normal; Ver:303242h; Serial:HWCD1622000524;
            + FRU-Part-Number:CA01022-0850/7334651      ;
            + Power_Status:ON; AC:200 V; Type: C ;
        PSU#3 Status:Normal; Ver:303242h; Serial:HWCD1622000496;
            + FRU-Part-Number:CA01022-0850/7334651      ;
            + Power_Status:ON; AC:200 V; Type: C ;
        FANU#0 Status:Normal; Type: C ;
        FANU#1 Status:Normal; Type: C ;
        FANU#2 Status:Normal; Type: C ;
        FANU#3 Status:Normal; Type: C ;
        FANU#4 Status:Normal; Type: C ;
        FANU#5 Status:Normal; Type: C ;
        FANU#6 Status:Normal; Type: C ;
        FANU#7 Status:Normal; Type: C ;
        HDDBP Status:Normal; Type: A ;
XSCF>        
*1 SPARC M12 model information
*2 System serial number and OPNL mode
*3 System operation status
*4 System information including the serial number, CPU information, and memory capacity of the SPARC M12-2S operating with BB-ID#00
*5 CMUL hardware information
*6 Information on the PCIe card mounted in the SPARC M12-2S with BB-ID#00
Checking hardware RAID volumes
To check the configuration or status of the hardware RAID volumes using the hardware RAID function featured by the SPARC M12-2/M12-2S, log in to Oracle Solaris on the control domain or root domain. Check the contents displayed by the sas2ircu command of the SAS2IRCU utility.
Before performing maintenance on the hardware RAID volumes, be sure to make a note of the hardware RAID setting information and information on the HDD/SSD composing the RAID volumes.
For details on how to obtain the SAS2IRCU utility and the user guide, see "Obtaining SAS-2 Integrated RAID Configuration Utility" in the latest version of the Fujitsu SPARC M12 Product Notes.
The following example shows the display by the sas2ircu command.
root# ./sas2ircu 1 display
LSI Corporation SAS2 IR Configuration Utility.
Version 20.00.00.00 (2014.09.18)
Copyright (c) 2008-2014 LSI Corporation. All rights reserved.
Read configuration has been initiated for controller 1
------------------------------------------------------------------------

Controller information
------------------------------------------------------------------------

  Controller type                         : SAS2308_2
  BIOS version                            : 0.00.00.00
  Firmware version                        : 20.00.10.00
  Channel description                     : 1 Serial Attached SCSI
  Initiator ID                            : 0
  Maximum physical devices                : 255
  Concurrent commands supported           : 3072
  Slot                                    : Unknown
  Segment                                 : 0
  Bus                                     : 3
  Device                                  : 0
  Function                                : 0
  RAID Support                            : Yes
------------------------------------------------------------------------

IR Volume information
------------------------------------------------------------------------

IR volume 1
  Volume ID                               : 286
  Volume Name                             : RAID1-Vol
  Status of volume                        : Okay (OKY)
  Volume wwid                             : 002c57a43e55a4a6
  RAID level                              : RAID1
  Size (in MB)                            : 571250
  Physical hard disks                     :
  PHY[0] Enclosure#/Slot#                 : 2:4
  PHY[1] Enclosure#/Slot#                 : 2:5
------------------------------------------------------------------------

Physical device information
------------------------------------------------------------------------

Initiator at ID #0
Device is a Enclosure services device
  Enclosure #                             : 2
  Slot #                                  : 0
  SAS Address                             : 500000e-0-e0b0-0a7d
  State                                   : Standby (SBY)
  Manufacturer                            : FUJITSU
  Model Number                            : BBEXP
  Firmware Revision                       : 1303
  Serial No                               : x3601930
  GUID                                    : N/A
  Protocol                                : SAS
  Device Type                             : Enclosure services device
Device is a Hard disk
  Enclosure #                             : 2
  Slot #                                  : 4
  SAS Address                             : 5000039-6-9800-24c2
  State                                   : Optimal (OPT)
  Size (in MB)/(in sectors)               : 572325/1172123567
  Manufacturer                            : TOSHIBA
  Model Number                            : AL13SEB600AL14SE
  Firmware Revision                       : 37E2
  Serial No                               : X510A007F7TD
  GUID                                    : 50000396980024c1
  Protocol                                : SAS
  Drive Type                              : SAS_HDD
Device is a Hard disk
  Enclosure #                             : 2
  Slot #                                  : 5
  SAS Address                             : 5000039-6-c828-404e
  State                                   : Optimal (OPT)
  Size (in MB)/(in sectors)               : 572325/1172123567
  Manufacturer                            : TOSHIBA
  Model Number                            : AL13SEB600
  Firmware Revision                       : 3703
  Serial No                               : 16I0A015FW28
  GUID                                    : 50000396c828404c
  Protocol                                : SAS
  Drive Type                              : SAS_HDD
------------------------------------------------------------------------

Enclosure information
------------------------------------------------------------------------

  Enclosure#                              : 1
  Logical ID                              : 500000e0:e06200a8
  Numslots                                : 8
  StartSlot                               : 0
  Enclosure#                              : 2
  Logical ID                              : 500000e0:e0b00a7f
  Numslots                                : 9
  StartSlot                               : 0
------------------------------------------------------------------------

SAS2IRCU: Command DISPLAY Completed Successfully.
SAS2IRCU: Utility Completed Successfully.