4.4.6 Inactive/Cold Replacement Workflow of the HDD/SSD
4.4.6 Inactive/Cold Replacement Workflow of the HDD/SSD
You can perform inactive/cold replacement of the HDD/SSD in the following configuration:
- Building block configuration where two or more physical partitions are operating
Before replacing the HDD/SSD, see "Precautions for HDD/SSD replacement" in "7.1 Precautions for FRU Replacement."
Table 4-34 shows the workflow for inactive/cold replacement of the HDD/SSD.
Work Order | Task | Reference |
---|---|---|
1 | Checking the operating condition of the system | "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains" |
2 | Confirming the HDD/SSD to be replaced | "8.2 Troubleshooting" |
3 | Checking the operation status of the SPARC M12-2S that houses the HDD/SSD to be replaced | "Figure 2-16 LED Locations on the HDD/SSD" |
4 | Powering off the physical partition containing the SPARC M12-2S that houses the HDD/SSD requiring maintenance | "9.5.1 Stopping a Specific Physical Partition" |
5 | Switching the mode switch on the OPNL to Service | "2.3.2 OPNL Control Function" |
6 | Releasing the SPARC M12-2S requiring maintenance from the building block configuration | "9.6.1 Releasing the SPARC M12-2S From the Building Block Configuration" |
7 | Placing the SPARC M12-2S requiring maintenance into the cold state | "9.8.2 Removing the Power Cords" |
8 | Removing the HDD/SSD from the SPARC M12-2S | "15.3.1 Removing an HDD/SSD" |
9 | Installing an HDD/SSD in the SPARC M12-2S | "15.4.1 Installing an HDD/SSD" |
10 | Placing the SPARC M12-2S that required maintenance into the hot state | "10.1.1 Installing a Power Cord" |
11 | Incorporating the SPARC M12-2S that required maintenance into the building block configuration | "10.4.1 Incorporating the SPARC M12-2S Into a Building Block Configuration" |
12 | Diagnosing the SPARC M12-2S requiring maintenance | "10.5.1 Diagnosing the SPARC M12 Hardware" |
13 | Powering on the physical partition containing the SPARC M12-2S that underwent maintenance | "10.8 Powering on a Physical Partition" (*1) |
14 | Confirming that there is no problem with the replacement HDD/SSD | "10.5.3 Checking the FRU Status After Maintenance" |
15 | Switching the mode switch on the OPNL to Locked | "2.3.2 OPNL Control Function" |
16 | Checking the operating condition of the system | "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains" |
*1 Do not switch the mode switch on the OPNL to Locked at this point. |