5.6.5 System-Stopped/Cold Addition Workflow of the PCI Expansion Unit
5.6.5 System-Stopped/Cold Addition Workflow of the PCI Expansion Unit
Before adding the PCI expansion unit, mount it in the rack. (See "3.3 Mounting the SPARC M12-2 and the PCI Expansion Unit in a Rack" in the Fujitsu SPARC M12-2 Installation Guide or "3.4 Mounting the SPARC M12-2S and the PCI Expansion Unit in a Rack" in the Fujitsu SPARC M12-2S Installation Guide.)
Table 5-26 shows the workflow for system-stopped/cold addition of a PCI expansion unit.
Table 5-26 shows the workflow for system-stopped/cold addition of a PCI expansion unit.
Work Order | Task | Reference |
---|---|---|
1 | Powering off all physical partitions | "9.5.2 Stopping All Physical Partitions" |
2 | Switching the mode switch on the OPNL to Service | "2.3.2 OPNL Control Function" |
3 | Removing the power cords of all the SPARC M12-2/M12-2S units | "9.8.2 Removing the Power Cords" |
4 | Removing the PCICS from the SPARC M12-2/M12-2S | "12.3.1 Enabling the Removal of a PCIe Card" |
5 | Removing the PCIe card filler from the PCICS | "12.3.2 Removing a PCIe Card or PCIe Card Filler" |
6 | Installing the link card in the PCICS | "12.4.1 Installing a PCIe Card or PCIe Card Filler" |
7 | Installing the link card in the SPARC M12-2/M12-2S | "12.4.2 Incorporating a PCIe Card Into the System" |
8 | Connecting a PCI expansion unit to the link card | "4.2 Connecting Cables to the PCI Expansion Unit" in the Fujitsu SPARC M12-2 Installation Guide or "5.2 Connecting Cables to the PCI Expansion Unit" in the Fujitsu SPARC M12-2S Installation Guide |
9 | Installing a PCIe card in the PCI expansion unit. | "12.4.1 Installing a PCIe Card or PCIe Card Filler" |
10 | Connecting the power cords of all the SPARC M12-2/M12-2S units | "10.1.1 Installing a Power Cord" |
11 | Diagnosing the SPARC M12-2/M12-2S with the added PCI expansion unit | "10.5.1 Diagnosing the SPARC M12 Hardware" |
12 | Confirming that there is no problem with the added PCI expansion unit | "10.5.3 Checking the FRU Status After Maintenance" |
13 | Switching the mode switch on the OPNL to Locked | "2.3.2 OPNL Control Function" |
14 | Powering on all physical partitions | "10.9.1 Starting the System With an XSCF Command" |
15 | Assigning the I/O resource to a logical domain | "3.2 Operations and Commands Related to Logical Domain Configurations" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide |