Table 5-1 shows the workflow for active/hot addition of a PCIe card using the PCI Hot Plug function.
Table 5-1  Active/Hot Addition Procedure of a PCIe Card
Work Order Task Reference
1 Checking the operating condition of the system "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
2 Switching the mode switch on the OPNL to Service "2.3.2 OPNL Control Function"
3 Removing the PCICS from the SPARC M12-2/M12-2S or PCI expansion unit "12.3.1 Enabling the Removal of a PCIe Card"
4 Removing the PCIe card filler of the PCICS "12.3.2 Removing a PCIe Card or PCIe Card Filler"
5 Installing a PCIe card in the PCICS to install it in the SPARC M12-2/M12-2S or PCI expansion unit "12.4.1 Installing a PCIe Card or PCIe Card Filler"
6 Incorporating the added PCIe card into the system "10.6.2 Incorporating an I/O Device Into the Physical Partition by Using the Hot Plug Function"
7 Confirming that there is no problem with the added PCIe card "10.5.3 Checking the FRU Status After Maintenance"
8 Switching the mode switch on the OPNL to Locked "2.3.2 OPNL Control Function"
9 Assigning the I/O resource to a logical domain "3.2 Operations and Commands Related to Logical Domain Configurations" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide