Table 4-53 shows the workflow for system-stopped/cold replacement of a PCIe card.
Table 4-53  System-Stopped/Cold Replacement Procedure of a PCIe Card
Work Order Task Reference
1 Checking the operating condition of the system "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
2 Confirming the PCIe card to be replaced "8.2 Troubleshooting"
3 Checking the operation status of the SPARC M12-2/M12-2S that houses the PCIe card to be replaced "Table 2-21 PCIe Card Slot LEDs and Their States"
4 Stopping all physical partitions "9.5.2 Stopping All Physical Partitions"
5 Switching the mode switch on the OPNL to Service "2.3.2 OPNL Control Function"
6 Removing the power cords of all the SPARC M12-2/M12-2S units "9.8.2 Removing the Power Cords"
7 Removing the faulty PCIe card from the SPARC M12-2/M12-2S "12.3.1 Enabling the Removal of a PCIe Card"
8 Removing the faulty PCIe card from the PCICS "12.3.2 Removing a PCIe Card or PCIe Card Filler"
9 Installing the replacement PCIe card in the PCICS to install it in the SPARC M12-2/M12-2S or PCI expansion unit "12.4.1 Installing a PCIe Card or PCIe Card Filler"
10 Installing the power cords on all the SPARC M12-2/M12-2S units "10.1.1 Installing a Power Cord"
11 Diagnosing all the SPARC M12-2/M12-2S units "10.5.1 Diagnosing the SPARC M12 Hardware"
12 Confirming that there is no problem with the replacement PCIe card "10.5.3 Checking the FRU Status After Maintenance"
13 Switching the mode switch on the OPNL to Locked "2.3.2 OPNL Control Function"
14 Powering on the physical partitions "10.9.1 Starting the System With an XSCF Command"
15 Checking the operating condition of the system "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"