9.6.2 Releasing the FANU
9.6.2 Releasing the FANU
This section describes the procedure for releasing the FANU of the SPARC M12.
- Log in to the XSCF shell.
- Execute the replacefru command to display the maintenance menu.
XSCF> replacefru |
- With a number key, select the FRU requiring maintenance.
Enter "1" to perform maintenance on the FANU of the SPARC M12-2 (BB#0).
------------------------------------------------------------------------------ Maintenance/Replacement Menu Please select the chassis including replaced FRU. No. FRU Status --- ------------------- -------------- 1 /BB#0 Normal 2 /BB#1 Unmount 3 /BB#2 Unmount 4 /BB#3 Unmount ------------------------------------------------------------------------------ Select [1-4|c:cancel] :1 |
- With a number key, select the FRU requiring maintenance.
Enter "2" to perform maintenance on the FANU of the SPARC M12-2.
------------------------------------------------------------------------------ Maintenance/Replacement Menu Please select the BB or a type of FRU to be replaced. 1. BB itself 2. FAN (Fan Unit) 3. PSU (Power Supply Unit) 4. XSCFU (Extended System Control Facility Unit) 5. Crossbar cable ------------------------------------------------------------------------------ Select [1-5|c:cancel] :2 |
- With a number key, select the faulty FRU.
Enter "1" since a fault has been confirmed in FANU#0 of BB#0.
------------------------------------------------------------------------------ Maintenance/Replacement Menu Please select a FRU to be replaced. No. FRU Status --- ------------------- -------------- 1 /BB#0/FANU#0 Faulted 2 /BB#0/FANU#1 Normal 3 /BB#0/FANU#2 Normal 4 /BB#0/FANU#3 Normal 5 /BB#0/FANU#4 Normal 6 /BB#0/FANU#5 Normal 7 /BB#0/FANU#6 Normal 8 /BB#0/FANU#7 Normal ------------------------------------------------------------------------------ Select [1-8|b:back] :1 |
- Confirm that the selected FRU is displayed, and then enter "r".
You are about to replace BB#0/FANU#0. Do you want to continue?[r:replace|c:cancel] :r |
- Remove the FANU to be replaced, as instructed in the output message.
Please execute the following steps: 1) Confirm the Check LED is blinking. 2) Remove BB#0/FANU#0. 3) Execute either the following: 3-1) After installing the exchanged device, please select 'finish'. 3-2) If you want to suspend the maintenance without exchanging device, please select 'cancel'. [f:finish|c:cancel] : |
Do not enter "f" until you mount the replacement FANU.
After mounting the replacement FANU, incorporate it into the SPARC M12-2/M12-2S by using the procedure described in "10.4.2 Incorporating the FANU."