9.6.2 Releasing the FANU


9.6.2 Releasing the FANU
This section describes the procedure for releasing the FANU of the SPARC M12.
  1. Log in to the XSCF shell.
  2. Execute the replacefru command to display the maintenance menu.
XSCF> replacefru
  1. With a number key, select the FRU requiring maintenance.
    Enter "1" to perform maintenance on the FANU of the SPARC M12-2 (BB#0).
------------------------------------------------------------------------------

Maintenance/Replacement Menu
Please select the chassis including replaced FRU.

No. FRU Status
--- ------------------- --------------

1 /BB#0 Normal
2 /BB#1 Unmount
3 /BB#2 Unmount
4 /BB#3 Unmount
------------------------------------------------------------------------------

Select [1-4|c:cancel] :1
  1. With a number key, select the FRU requiring maintenance.
    Enter "2" to perform maintenance on the FANU of the SPARC M12-2.
------------------------------------------------------------------------------

Maintenance/Replacement Menu
Please select the BB or a type of FRU to be replaced.
1. BB itself

2. FAN (Fan Unit)

3. PSU (Power Supply Unit)

4. XSCFU (Extended System Control Facility Unit)

5. Crossbar cable

------------------------------------------------------------------------------

Select [1-5|c:cancel] :2
  1. With a number key, select the faulty FRU.
    Enter "1" since a fault has been confirmed in FANU#0 of BB#0.
------------------------------------------------------------------------------

Maintenance/Replacement Menu
Please select a FRU to be replaced.
No. FRU Status
--- ------------------- --------------

1 /BB#0/FANU#0 Faulted
2 /BB#0/FANU#1 Normal
3 /BB#0/FANU#2 Normal
4 /BB#0/FANU#3 Normal
5 /BB#0/FANU#4 Normal
6 /BB#0/FANU#5 Normal
7 /BB#0/FANU#6 Normal
8 /BB#0/FANU#7 Normal
------------------------------------------------------------------------------

Select [1-8|b:back] :1
  1. Confirm that the selected FRU is displayed, and then enter "r".
You are about to replace BB#0/FANU#0.
Do you want to continue?[r:replace|c:cancel] :r
  1. Remove the FANU to be replaced, as instructed in the output message.
Please execute the following steps:
1) Confirm the Check LED is blinking.
2) Remove BB#0/FANU#0.
3) Execute either the following:
3-1) After installing the exchanged device, please select 'finish'.
3-2) If you want to suspend the maintenance without exchanging device,
please select 'cancel'.
[f:finish|c:cancel] :
Do not enter "f" until you mount the replacement FANU.
After mounting the replacement FANU, incorporate it into the SPARC M12-2/M12-2S by using the procedure described in "10.4.2 Incorporating the FANU."