  9. 10.3 Adding the SPARC M12-2S to a Building Block Configuration

10.3 Adding the SPARC M12-2S to a Building Block Configuration


10.3 Adding the SPARC M12-2S to a Building Block Configuration
Note - When adding the SPARC M12-2S due to a change in the building block configuration, be sure to perform the procedure described below.
Note - To add a SPARC M12-2S with 64 GB DIMMs mounted, see "Notes on Memory" in the latest version of the Fujitsu SPARC M12 Product Notes.
This section describes the procedure for adding the SPARC M12-2S to BB#2 of the building block configuration.
The added SPARC M12-2S is incorporated into the building block configuration in the factory-default state. When you add a newly purchased SPARC M12-2S, do not connect power cords until instructed so. If the SPARC M12-2S to be added has been used in another system, be sure to reset it to its factory-default state by using the restoredefaults or initbb command and do not connect power cords until instructed so.
To perform system-stopped/cold addition of the SPARC M12-2S to a building block configuration, see "5.6.6 System-Stopped/Cold Addition Workflow of the SPARC M12-2S."
For details on the commands used here, see the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 XSCF Reference Manual of the XCP version used.

  1. Check the operation status of the building block configuration.
    Log in to the master XSCF, and check the operation status of the building block configuration by using the showboards command.
    The following example shows that BB#00 and BB#01 are connected to the building block configuration.
XSCF> showboards -a -v
PSB R PPAR-ID(LSB) Assignment Pwr Conn Conf Test Fault
---- - ------------ ----------- ---- ---- ---- ------- --------

00-0 00(00) Assigned y y y Passed Normal
01-0 00(01) Assigned y y y Passed Normal

XSCF>
  1. Set a BB-ID for the SPARC M12-2S.
    Based on the check result in step 1, set the BB-ID of the SPARC M12-2S to be added to "02". For details on how to set a BB-ID, see "2.3 Understanding the OPNL Functions."
  2. Prepare for the addition of the SPARC M12-2S.
    Log in to the master XSCF, and add the SPARC M12-2S to the building block configuration by using the addfru command.
XSCF> addfru

------------------------------------------------------------------------------

Maintenance/Addition Menu
Please select the chassis including added FRU.

No. FRU Status
--- ------------------- --------------

1 /BB#0 Normal

2 /BB#1 Normal

3 /BB#2 Unmount

4 /BB#3 Unmount

------------------------------------------------------------------------------

Select [1-4|c:cancel] :3‍ ← (*1)


------------------------------------------------------------------------------

Maintenance/Addition Menu
Please select the BB or a type of FRU to be added.

1. BB itself

2. PSU (Power Supply Unit)

------------------------------------------------------------------------------

Select [1,2|c:cancel] :1‍ ← (*2)


------------------------------------------------------------------------------

Maintenance/Addition Menu
Please select a FRU to be added.

No. FRU Status
--- ------------------- --------------

1 /BB#2 Unmount

------------------------------------------------------------------------------

Select [1|b:back] :1‍ ← (*3)

You are about to add BB#2.
Do you want to continue?[a:add|c:cancel] :a‍ ← (*4)

Please execute the following steps:
1) After the added device is connected with the system,
please turn on the breaker of the BB#2.
2) Please select[f:finish] :‍ ← (*5)
*1 Select the BB-ID to be added. Here, select BB#2.
*2 To add the SPARC M12-2S, select "BB itself".
*3 Check that the SPARC M12-2S is not connected to BB#2.
*4 Enter "a" to start the operation of adding the SPARC M12-2S to BB#2.
*5 Do not enter anything until step 4 is complete.
  1. Connect the cables to the SPARC M12-2S to be added.
    Connect the XSCF BB control cable and crossbar cable to the SPARC M12-2S to be added. If the added SPARC M12-2S will operate as the standby XSCF, also connect the XSCF DUAL control cable.
    After connecting the XSCF BB control cable, XSCF DUAL control cable, and crossbar cable, connect the power cord and start the XSCF. When you have done this, check that the READY LED on the XSCFU is blinking. For details, see the part about the XSCF unit in "2.4.3 LEDs of Each Unit."
Note - For information on the connection of the various cables, see "Appendix A Lists of Cable Connections in a Building Block Configuration."
  1. Incorporate the SPARC M12-2S into the building block configuration.
    When you have the cables and power cord connected to the SPARC M12-2S to be added and the READY LED blinking on the XSCFU, continue the operation of step 3.
    Note that incorporating the SPARC M12-2S into the building block configuration makes the READY LED on the XSCFU stay lit.
Please execute the following steps:
1) After the added device is connected with the system,
please turn on the breaker of the BB#2.
2) Please select[f:finish] :f‍ ← (*6)

Waiting for BB#2 to enter install state.
[This operation may take up to 20 minute(s)]
(progress scale reported in seconds)
0..... 30..... 60..... 90..... 120..... 150..... 180..... 210.....
240..... 270..... 300..... 330..... 360..... 390..... 420..... 450.....

480..... 510..... 540..... 570..... 600..... 630. done


Waiting for BB#2 to enter ready state.
[This operation may take up to 45 minute(s)]
(progress scale reported in seconds)
0..... 30..... 60..... 90..... 120..... 150..... 180..... 210.....
240.... done


Do you want to start to diagnose BB#2?[s:start|c:cancel] :s‍ ← (*7)

Diagnostic tests for BB#2 have started.
Initial diagnosis is about to start, Continue?[y|n] :y‍ ← (*8)
PSB#02-0 power on sequence started.
0..... 30....end
Initial diagnosis started. [1 / 2] [7200sec]
0..... 30..... 60..... 90.....120.....150.....180.....210.....240...../
270.....300.....330....end

Initial diagnosis has completed.
PSB power off sequence started. [1200sec]
0..... 30..... 60...end
PSB powered off.
PSB#02-0 power on sequence started.
0..... 30...end
Initial diagnosis started. [2 / 2] [7200sec]
0..... 30..... 60..... 90.....120.....150.....180.....210.....240...../
270..end

Initial diagnosis has completed.
PSB power off sequence started. [1200sec]
0..... 30..... 60...end
PSB powered off.
PSB Test Fault
---- ------- --------

02-0 Passed Normal
done


------------------------------------------------------------------------------ Maintenance/Addition Menu

Please select the chassis including added FRU.
No. FRU Status
--- ------------------- --------------

1 /BB#0 Normal

2 /BB#1 Normal

3 /BB#2 Normal

4 /BB#3 Unmount

------------------------------------------------------------------------------

Select [1-4|c:cancel] :c‍ ← (*9)
*6 Enter "f" to start the operation of incorporating the SPARC M12-2S into the building block configuration.
*7 Check whether to perform the hardware diagnosis on the added SPARC M12-2S. If the added SPARC M12-2S has a PCIe card mounted, cancel the hardware diagnosis, and temporarily complete the incorporation process. If you cancel the hardware diagnosis, see "10.5.1 Diagnosing the SPARC M12 Hardware" and perform the diagnosis before incorporating the added SPARC M12-2S into the physical partition.
*8 Enter "y" to start the hardware diagnosis.
*9 Enter "c" to end the addfru command.
  1. Check the status of the building block configuration.
    From the master XSCF, check the status of the building block configuration by using the showboards command. If you cancel the hardware diagnosis in step 5, "Unknown" is displayed in the Test column.
XSCF> showboards -a -v
PSB R PPAR-ID(LSB) Assignment Pwr Conn Conf Test Fault
---- - ------------ ----------- ---- ---- ---- ------- --------

00-0 00(00) Assigned y y y Passed Normal
01-0 00(01) Assigned y y y Passed Normal
02-0 SP Available n n n Passed Normal

XSCF>
  1. Check the hardware configuration information.
    From the master XSCF, check the hardware configuration of the SPARC M12-2S added to the building block configuration, by using the showhardconf command.
    If there is a hardware error, an asterisk (*) appears in front of the corresponding FRU name. Remove the cause of the error by using the replacefru or other appropriate command, before proceeding with the system operation.
XSCF> showhardconf
SPARC M12-2S;
+ Serial:PZ51618004; Operator_Panel_Switch:Locked;
+ System_Power:On; System_Phase:Cabinet Power On;
Partition#0 PPAR_Status:Running;
BB#00 Status:Normal; Role:Master; Ver:300ch; Serial:PZ51618004;
+ FRU-Part-Number:CA20369-B17X 003AB/9999999 ;
+ Power_Supply_System: ;
+ Memory_Size:256 GB;
CMUL Status:Normal; Ver:1101h; Serial:PP16170119 ;
+ FRU-Part-Number:CA07855-D201 A1 /9999999 ;
+ Memory_Size:128 GB; Type: C ;
(Omitted)
BB#01 Status:Normal; Role:Standby; Ver:300ch; Serial:PZ51617007;
+ FRU-Part-Number:CA20369-B17X 003AB/9999999 ;
+ Power_Supply_System: ;
+ Memory_Size:256 GB;
CMUL Status:Normal; Ver:1101h; Serial:PP1617010X ;
+ FRU-Part-Number:CA07855-D201 A1 /9999999 ;
+ Memory_Size:128 GB; Type: C ;
(Omitted)
BB#02 Status:Normal; Role:Slave; Ver:300ch; Serial:PZ51617011;
+ FRU-Part-Number:CA20369-B17X 003AB/9999999 ;
+ Power_Supply_System: ;
+ Memory_Size:128 GB;
CMUL Status:Normal; Ver:1101h; Serial:PP1617010U ;
+ FRU-Part-Number:CA07855-D201 A1 /9999999 ;
+ Memory_Size:128 GB; Type: C ;
CPU#0 Status:Normal; Ver:4241h; Serial:00000056;
+ Freq:4.250 GHz; Type:0x30;
+ Core:12; Strand:8;
(Omitted)
  1. Assign the CPU core resources.
    Assign the CPU core resources of the added SPARC M12-2S to physical partitions.
    If you cannot assign the CPU core resources, check whether a CPU Activation key is registered. For details, see "Chapter 5 CPU Activation" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 System Operation and Administration Guide.