You can perform active/cold addition of the HDD/SSD in the following configuration:
  1. Configuration connecting two or more SPARC M12-2S units to a physical partition
Table 5-5 shows the workflow for active/cold addition of the HDD/SSD.
Table 5-5   Active/Cold Addition Procedure of the HDD/SSD
Work Order Task Reference
1 Checking the operating condition of the system "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains"
2 Checking the logical domain assignment status of CPU resources mounted in the SPARC M12-2S requiring maintenance "3.2.4 Checking the Assignment Status of Resources" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide
3 Checking the logical domain assignment status of memory resources mounted in the SPARC M12-2S requiring maintenance "3.2.4 Checking the Assignment Status of Resources" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide
4 Releasing the logical domain assignment of PCIe cards mounted in the SPARC M12-2S requiring maintenance "9.3 Releasing I/O Resources From a Logical Domain"
5 Releasing the SPARC M12-2S requiring maintenance from the physical partition "9.4.3 Dynamically Releasing the SPARC M12-2S From the Physical Partition"
6 Switching the mode switch on the OPNL to Service "2.3.2 OPNL Control Function"
7 Releasing the SPARC M12-2S requiring maintenance from the building block configuration, and removing the power cords "9.6.1 Releasing the SPARC M12-2S From the Building Block Configuration"
"9.8.2 Removing the Power Cords"
8 Removing the filler unit from the SPARC M12-2S "15.3.2 Removing a Filler Unit"
9 Installing an HDD/SSD in the SPARC M12-2S "15.4.1 Installing an HDD/SSD"
10 Installing the power cords on the SPARC M12-2S with the added HDD/SSD, and incorporating it into the building block configuration "10.1.1 Installing a Power Cord"
"10.4.1 Incorporating the SPARC M12-2S Into a Building Block Configuration"
11 Diagnosing the SPARC M12-2S with the added HDD/SSD "10.5.1 Diagnosing the SPARC M12 Hardware"
12 Confirming that there is no problem with the added HDD/SSD "10.5.3 Checking the FRU Status After Maintenance"
13 Incorporating the SPARC M12-2S with the added HDD/SSD into the physical partition "10.6.1 Incorporating the SPARC M12-2S Into the Physical Partition Using PPAR DR"
14 Switching the mode switch on the OPNL to Locked "2.3.2 OPNL Control Function"
15 Assigning the I/O resource to a logical domain "3.2 Operations and Commands Related to Logical Domain Configurations" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide