5.2.2 Active/Cold Addition Workflow of the HDD/SSD
5.2.2 Active/Cold Addition Workflow of the HDD/SSD
You can perform active/cold addition of the HDD/SSD in the following configuration:
- Configuration connecting two or more SPARC M12-2S units to a physical partition
Before adding the HDD/SSD, see "Precautions for HDD/SSD addition" in "7.2 Precautions for FRU Expansion."
Table 5-5 shows the workflow for active/cold addition of the HDD/SSD.
Work Order | Task | Reference |
---|---|---|
1 | Checking the operating condition of the system | "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains" |
2 | Checking the logical domain assignment status of CPU resources mounted in the SPARC M12-2S requiring maintenance | "3.2.4 Checking the Assignment Status of Resources" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide |
3 | Checking the logical domain assignment status of memory resources mounted in the SPARC M12-2S requiring maintenance | "3.2.4 Checking the Assignment Status of Resources" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide |
4 | Releasing the logical domain assignment of PCIe cards mounted in the SPARC M12-2S requiring maintenance | "9.3 Releasing I/O Resources From a Logical Domain" |
5 | Releasing the SPARC M12-2S requiring maintenance from the physical partition | "9.4.3 Dynamically Releasing the SPARC M12-2S From the Physical Partition" |
6 | Switching the mode switch on the OPNL to Service | "2.3.2 OPNL Control Function" |
7 | Releasing the SPARC M12-2S requiring maintenance from the building block configuration, and removing the power cords | "9.6.1 Releasing the SPARC M12-2S From the Building Block Configuration" "9.8.2 Removing the Power Cords" |
8 | Removing the filler unit from the SPARC M12-2S | "15.3.2 Removing a Filler Unit" |
9 | Installing an HDD/SSD in the SPARC M12-2S | "15.4.1 Installing an HDD/SSD" |
10 | Installing the power cords on the SPARC M12-2S with the added HDD/SSD, and incorporating it into the building block configuration | "10.1.1 Installing a Power Cord" "10.4.1 Incorporating the SPARC M12-2S Into a Building Block Configuration" |
11 | Diagnosing the SPARC M12-2S with the added HDD/SSD | "10.5.1 Diagnosing the SPARC M12 Hardware" |
12 | Confirming that there is no problem with the added HDD/SSD | "10.5.3 Checking the FRU Status After Maintenance" |
13 | Incorporating the SPARC M12-2S with the added HDD/SSD into the physical partition | "10.6.1 Incorporating the SPARC M12-2S Into the Physical Partition Using PPAR DR" |
14 | Switching the mode switch on the OPNL to Locked | "2.3.2 OPNL Control Function" |
15 | Assigning the I/O resource to a logical domain | "3.2 Operations and Commands Related to Logical Domain Configurations" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide |