5.4.1 Inactive/Cold Addition Workflow of a PCIe Card
5.4.1 Inactive/Cold Addition Workflow of a PCIe Card
You can perform inactive/cold addition of a PCIe card in the following configuration:
- Building block configuration where two or more physical partitions are operating
Before adding a PCIe card, see "Precautions for PCIe card addition" in "7.2 Precautions for FRU Expansion."
Table 5-13 shows the workflow for inactive/cold addition of a PCIe card.
Work Order | Task | Reference |
---|---|---|
1 | Checking the operating condition of the system | "9.2.1 Checking the Operation Status of Physical Partitions and Logical Domains" |
2 | Powering off the physical partition containing the SPARC M12-2S requiring maintenance | "9.5.1 Stopping a Specific Physical Partition" |
3 | Switching the mode switch on the OPNL to Service | "2.3.2 OPNL Control Function" |
4 | Releasing the SPARC M12-2S requiring maintenance from the building block configuration, and removing the power cords | "9.6.1 Releasing the SPARC M12-2S From the Building Block Configuration" "9.8.2 Removing the Power Cords" |
5 | Removing the PCICS from the SPARC M12-2S | "12.3.1 Enabling the Removal of a PCIe Card" |
6 | Removing the PCIe card filler from the PCICS | "12.3.2 Removing a PCIe Card or PCIe Card Filler" |
7 | Installing a PCIe card in the PCICS to install it in the SPARC M12-2S | "12.4.1 Installing a PCIe Card or PCIe Card Filler" |
8 | Installing the power cords on the SPARC M12-2S with the added PCIe card, and incorporating it into the building block configuration | "10.1.1 Installing a Power Cord" "10.4.1 Incorporating the SPARC M12-2S Into a Building Block Configuration" |
9 | Diagnosing the SPARC M12-2S with the added PCIe card | "10.5.1 Diagnosing the SPARC M12 Hardware" |
10 | Confirming that there is no problem with the added PCIe card | "10.5.3 Checking the FRU Status After Maintenance" |
11 | Switching the mode switch on the OPNL to Locked | "2.3.2 OPNL Control Function" |
12 | Powering on the physical partition of the added PCIe card | "10.9.1 Starting the System With an XSCF Command" |
13 | Assigning the I/O resource to a logical domain | "3.2 Operations and Commands Related to Logical Domain Configurations" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide |
< Previous Page | Next Page >