  9. 3.3.3 Types of Maintenance for FRU Removal (SPARC M12-2S in the 1BB Configuration)

3.3.3 Types of Maintenance for FRU Removal (SPARC M12-2S in the 1BB Configuration)


3.3.3 Types of Maintenance for FRU Removal (SPARC M12-2S in the 1BB Configuration)
Table 3-10 lists the FRUs that can be removed from the SPARC M12-2S (1BB configuration) and the applicable types of maintenance in the removal of each FRU.
Table 3-10  Applicable Types of Maintenance in FRU Removal for the SPARC M12-2S (1BB Configuration)
-: Not applicable
FRU Active Removal Inactive Removal System-Stopped Removal
Hot Cold Hot Cold Hot Cold
PCIe card OK - - - OK OK
HDD/SSD OK - - - OK OK
CMUU - - - - - OK
Memory - - - - - OK
PCI expansion unit (chassis) OK - - - OK OK
Active/Hot removal
Figure 3-22 shows the state of the system during active/hot removal in the SPARC M12-2S (1BB configuration).
Figure 3-22  Active/Hot Removal in the SPARC M12-2S (1BB Configuration)
Figure 3-22  Active/Hot Removal in the SPARC M12-2S (1BB Configuration)
System-Stopped/Hot removal
Figure 3-23 shows the state of the system during system-stopped/hot removal in the SPARC M12-2S (1BB configuration).
Figure 3-23  System-Stopped/Hot Removal in the SPARC M12-2S (1BB Configuration)
Figure 3-23  System-Stopped/Hot Removal in the SPARC M12-2S (1BB Configuration)
System-Stopped/Cold removal
Figure 3-24 shows the state of the system during system-stopped/cold removal in the SPARC M12-2S (1BB configuration).
Figure 3-24  System-Stopped/Cold Removal in the SPARC M12-2S (1BB Configuration)
Figure 3-24  System-Stopped/Cold Removal in the SPARC M12-2S (1BB Configuration)