F.8 Identifying the Faulty Disk Drive of a Hardware RAID Volume
F.8 Identifying the Faulty Disk Drive of a Hardware RAID Volume
Use the sas2ircu display command to identify the faulty hardware RAID volume and the faulty disk drive.
In the following example, the disk drive of disk slot 1 of the SPARC M10-1 is faulty.
In the examples that follow, (1) to (2) indicate the following:
(1-1): RAID volume 2 information
You can obtain the following information (partial extract).
(1): RAID volume information
(1-1): RAID volume 2 information
You can obtain the following information (partial extract).
- RAID volume ID is 286
- RAID volume status is Degraded (Degraded (DGD))
- RAID level is RAID1 (Mirroring)
- Disk (2:0) of SPARC M12/M10 internal disk slot 0 is mounted in PHY[0] (Primary)
- PHY[1] (Secondary) has no disk information (0:0)
(2): Physical device information
(2-1): Status of disk drive (Drive Type=SAS_HDD) that has no information on installation location (Enclosure#:0,Slot#:0 = previously existed as Enclosure#:2,Slot#:1 but was not accessible when this command was executed)
This indicates that the disk drive is out of order. (State:Failed (FLD))
root# ./sas2ircu 0 display LSI Corporation SAS2 IR Configuration Utility. Version 17.00.00.00 (2013.07.19) Copyright (c) 2009-2013 LSI Corporation. All rights reserved. Read configuration has been initiated for controller 0 ------------------------------------------------------------------------ Controller information ------------------------------------------------------------------------ Controller type : SAS2308_2 BIOS version : 0.00.00.00 Firmware version : 13.00.66.00 Channel description : 1 Serial Attached SCSI Initiator ID : 0 Maximum physical devices : 255 Concurrent commands supported : 3072 Slot : Unknown Segment : 0 Bus : 3 Device : 0 Function : 0 RAID Support : Yes ------------------------------------------------------------------------ IR Volume information <-- (1) ------------------------------------------------------------------------ IR volume 1 Volume ID : 285 Volume Name : RAID1E-VOL Status of volume : Okay (OKY) Volume wwid : 0fd4f41e8cd673de RAID level : RAID1E Size (in MB) : 856875 Physical hard disks : PHY[0] Enclosure#/Slot# : 2:2 PHY[1] Enclosure#/Slot# : 2:3 PHY[2] Enclosure#/Slot# : 2:4 IR volume 2 <-- (1-1) Volume ID : 286 Volume Name : RAID1-SYS Status of volume : Degraded (DGD) Volume wwid : 0aa6d102f1bf517a RAID level : RAID1 Size (in MB) : 571250 Physical hard disks : PHY[0] Enclosure#/Slot# : 2:0 PHY[1] Enclosure#/Slot# : 0:0 ------------------------------------------------------------------------ Physical device information <-- (2) ------------------------------------------------------------------------ Initiator at ID #0 Device is a Hard disk <-- (2-1) Enclosure # : 0 Slot # : 0 SAS Address : 0000000-0-0000-0000 State : Failed (FLD) Manufacturer : TOSHIBA Model Number : MBF2600RC Firmware Revision : 3706 Serial No : EA25PC700855 GUID : N/A Protocol : SAS Drive Type : SAS_HDD Device is a Enclosure services device Enclosure # : 2 Slot # : 0 SAS Address : 500000e-0-e049-073d State : Standby (SBY) Manufacturer : FUJITSU Model Number : NBBEXP Firmware Revision : 0d32 Serial No : x3625413500 GUID : N/A Protocol : SAS Device Type : Enclosure services device Device is a Hard disk Enclosure # : 2 Slot # : 0 SAS Address : 5000039-4-281b-6466 State : Optimal (OPT) Size (in MB)/(in sectors) : 572325/1172123567 Manufacturer : TOSHIBA Model Number : MBF2600RC Firmware Revision : 3706 Serial No : EA25PC7007UE GUID : 50000394281b6464 Protocol : SAS Drive Type : SAS_HDD Device is a Hard disk Enclosure # : 2 Slot # : 2 SAS Address : 5000039-4-281a-8ad2 State : Optimal (OPT) Size (in MB)/(in sectors) : 572325/1172123567 Manufacturer : TOSHIBA Model Number : MBF2600RC Firmware Revision : 3706 Serial No : EA25PC7007G7 GUID : 50000394281a8ad0 Protocol : SAS Drive Type : SAS_HDD Device is a Hard disk Enclosure # : 2 Slot # : 3 SAS Address : 5000039-4-281b-5dc2 State : Optimal (OPT) Size (in MB)/(in sectors) : 572325/1172123567 Manufacturer : TOSHIBA Model Number : MBF2600RC Firmware Revision : 3706 Serial No : EA25PC7007T3 GUID : 50000394281b5dc0 Protocol : SAS Drive Type : SAS_HDD Device is a Hard disk Enclosure # : 2 Slot # : 4 SAS Address : 5000039-4-281b-502e State : Optimal (OPT) Size (in MB)/(in sectors) : 572325/1172123567 Manufacturer : TOSHIBA Model Number : MBF2600RC Firmware Revision : 3706 Serial No : EA25PC7007LR GUID : 50000394281b502c Protocol : SAS Drive Type : SAS_HDD ------------------------------------------------------------------------ Enclosure information ------------------------------------------------------------------------ Enclosure# : 1 Logical ID : 500000e0:e046ff10 Numslots : 8 StartSlot : 0 Enclosure# : 2 Logical ID : 500000e0:e049073f Numslots : 9 StartSlot : 0 ------------------------------------------------------------------------ SAS2IRCU: Command DISPLAY Completed Successfully. SAS2IRCU: Utility Completed Successfully. root# |
Note - The following message may be displayed on Oracle Solaris after operating a RAID volume to create or delete a RAID volume, delete a hot spare, etc. This indicates that there is no label information on the RAID volume or the disk drive. The RAID volume or the disk drive in this state cannot be used on Oracle Solaris. It will be usable on Oracle Solaris after executing the format command, selecting the appropriate RAID volume or disk drive, and labeling it. |
- Example of output message
Jan 20 15:55:07 1S-341-D0 cmlb: WARNING: /scsi_vhci/disk@g50000394281a8ad0 (sd1): Jan 20 15:55:07 1S-341-D0 Corrupt label; wrong magic number |
- Example of executing the format command
root@solaris:/root# format Searching for disks... Jan 20 15:55:07 1S-341-D0 cmlb: WARNING: /scsi_vhci/disk@g50000394281a8ad0 (sd1): Jan 20 15:55:07 1S-341-D0 Corrupt label; wrong magic number Jan 20 15:55:07 1S-341-D0 cmlb: WARNING: /scsi_vhci/disk@g50000394281a8ad0 (sd1): Jan 20 15:55:07 1S-341-D0 Corrupt label; wrong magic number Jan 20 15:55:07 1S-341-D0 cmlb: WARNING: /scsi_vhci/disk@g50000394281b58b0 (sd3): Jan 20 15:55:07 1S-341-D0 Corrupt label; wrong magic number Jan 20 15:55:07 1S-341-D0 cmlb: WARNING: /scsi_vhci/disk@g50000394281b58b0 (sd3): Jan 20 15:55:07 1S-341-D0 Corrupt label; wrong magic number Jan 20 15:55:07 1S-341-D0 cmlb: WARNING: /scsi_vhci/disk@g50000394281b5dc0 (sd0): Jan 20 15:55:07 1S-341-D0 Corrupt label; wrong magic number Jan 20 15:55:08 1S-341-D0 cmlb: WARNING: /scsi_vhci/disk@g50000394281b5dc0 (sd0): Jan 20 15:55:08 1S-341-D0 Corrupt label; wrong magic number done c0t50000394281A8AD0d0: configured with capacity of 558.89GB c0t50000394281B5DC0d0: configured with capacity of 558.89GB c0t50000394281B58B0d0: configured with capacity of 558.89GB AVAILABLE DISK SELECTIONS: 0. c0t50000394281A8AD0d0 <TOSHIBA-MBF2600RC-3706 cyl 64986 alt 2 hd 27 sec 668> /scsi_vhci/disk@g50000394281a8ad0 /dev/chassis/SYS/HDD02/disk 1. c0t50000394281B5DC0d0 <TOSHIBA-MBF2600RC-3706 cyl 64986 alt 2 hd 27 sec 668> /scsi_vhci/disk@g50000394281b5dc0 /dev/chassis/SYS/HDD03/disk 2. c0t50000394281B58B0d0 <TOSHIBA-MBF2600RC-3706 cyl 64986 alt 2 hd 27 sec 668> /scsi_vhci/disk@g50000394281b58b0 /dev/chassis/SYS/HDD04/disk 3. c0t50000394281B5020d0 <LSI-Logical Volume-3000 cyl 24998 alt 2 hd 16 sec 128> /scsi_vhci/disk@g50000394281b5020 /dev/chassis/SYS/HDD05/disk 4. c2t3AA6D102F1BF517Ad0 <LSI-Logical Volume-3000 cyl 65533 alt 2 hd 32 sec 557> /pci@8000/pci@4/pci@0/pci@0/scsi@0/iport@v0/disk@w3aa6d102f1bf517a,0 Specify disk (enter its number): 0 [disk formatted] Disk not labeled. Label it now? yes |