11.1.5 Displaying the PCI Expansion Unit Status
11.1.5 Displaying the PCI Expansion Unit Status
This section describes how to check the PCI expansion unit connected to the system, the parts in the PCI expansion unit, a link card mounted in a built-in PCI slot of the system, and the PCI expansion unit status.
You can check the PCI expansion unit status and settings by using the ioxadm command.
You can check the PCI expansion unit status and settings by using the ioxadm command.
Note - For details of the PCI expansion unit hardware configuration, see "Chapter 2 Understanding the PCI Expansion Unit Components" in the PCI Expansion Unit for Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Service Manual. For details or usage examples of the ioxadm command, see the ioxadm(8) command man page or the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 XSCF Reference Manual. |
Displayed Information
Table 11-6 outlines the information displayed by the executed ioxadm command.
Display Item | Description |
---|---|
List display (list) |
- List of paths (host_path) between the PCI expansion unit and link cards mounted in chassis slots - Detailed information on the PCI expansion unit - Detailed information on FRUs (I/O board, power supply unit, etc.) in the PCI expansion unit The displayed information includes the FRU type, firmware version, serial number, part number, and status. |
Environment display (env) |
- Environmental conditions according to sensor measurement values of the specified PCI expansion unit or link card - Environment information on FRUs in the PCI expansion unit or cards mounted in PCI slots The displayed information includes the following: - Current (A) - Voltage (V) - Fan speed (RPM) - Temperature (C) - LED status - SWITCH |
Locator LED display (locator) |
- Locator LED states of the specified PCI expansion unit and each part in the PCI expansion unit The locator LED states are as follows: - Blinking - On - Off |
Version comparison result (versionlist) |
Displays the PCI expansion unit firmware version, connection destination link card firmware version, and the result of comparing these firmware. The comparison results are as follows. - equal - mismatch |
List Display
The procedure for displaying a list of the PCI expansion unit, I/O boards, link cards, and power supply units is described below.
- Execute the ioxadm command to check the PCI expansion unit and link cards.
In the following example, a list of all PCI expansion units and link cards is displayed.
XSCF> ioxadm list PCIBOX Link PCIBOX#0033 BB#00-PCI#1 PCIBOX#12B4 BB#01-PCI#0 |
- The following example displays a single PCI expansion unit.
XSCF> ioxadm list PCIBOX#12B4 PCIBOX Link PCIBOX#12B4 BB#01-PCI#0 |
- The following example uses host_path to display cards in detailed output mode with the headers hidden.
XSCF> ioxadm -A -v list BB#00-PCI#1 BB#00-PCI#1 F20 - 000004 5111500-01 On |
Environment Display
The procedure for displaying the environment by using sensor measurement values is described below.
- Execute the ioxadm command to check environment information.
The following example displays the sensor measurement values of temperature, voltage, current, fan speed, etc.
XSCF> ioxadm env -te PCIBOX#A3B4 Location Sensor Value Res Units PCIBOX#A3B4/PSU#0 FAN 3224.324 – RPM PCIBOX#A3B4/PSU#1 FAN 3224.324 – RPM PCIBOX#A3B4/FAN#0 FAN 3522.314 – RPM PCIBOX#A3B4/FAN#1 FAN 3522.314 – RPM PCIBOX#A3B4/FAN#2 FAN 3522.314 – RPM PCIBOX#A3B4/FAN#0 FAN 3522.314 – RPM PCIBOX#A3B4/IOBT T_INTAKE 32.000 – C PCIBOX#A3B4/IOBT T_PART_NO1 32.000 – C PCIBOX#A3B4/IOBT T_PART_NO2 32.000 – C PCIBOX#A3B4/IOBT T_PART_NO3 32.000 – C PCIBOX#A3B4/IOBT V_12_0V 12.400 – V PCIBOX#A3B4/IOBT V_3_3_NO0 3.320 – V PCIBOX#A3B4/IOBT V_3_3_NO1 3.310 – V PCIBOX#A3B4/IOBT V_3_3_NO2 3.310 – V PCIBOX#A3B4/IOBT V_3_3_NO3 3.320 – V PCIBOX#A3B4/IOBT V_1_8V 1.820 – V PCIBOX#A3B4/IOBT V_0_9V 0.910 – V |
- The following example displays all the sensor measurement values relating to one link.
XSCF> ioxadm -A env BB#00-PCI#1 BB#00-PCI#1 LINK On - LED BB#00-PCI#1 MGMT On - LED |
Location Display
The procedure for displaying the locator LED states of the PCI expansion unit and specified parts is described below.
- Execute the ioxadm command to check the PCI expansion unit status.
The following example displays the locator LED state of the PCI expansion unit.
XSCF> ioxadm locator PCIBOX#12B4 Location Sensor Value Resolution Units PCIBOX#12B4 LOCATE Blink - LED |
Version Comparison Result
The method of displaying the PCI expansion unit firmware version, connection destination link card firmware version, and the comparison result is as follows.
- Execute the ioxadm command to confirm the PCI expansion unit firmware version, connection destination link card firmware version, and the comparison result.
In the following example, the result of comparing all PCI expansion units and link cards is displayed.
XSCF> ioxadm versionlist PCIBOX Ver. Link Ver. Info PCIBOX#0033 1010 BB#00-PCI#1 1010 equal * PCIBOX#12B4 1010 BB#00-PCI#0 1011 mismatch |
< Previous Page | Next Page >