Skip to main content

11.1.2 Checking Mounted Components in the System


11.1.2 Checking Mounted Components in the System
You can check all the mounted components in the system and their status by using the showhardconf command. The command displays an asterisk (*) to mark a part that has a problem. The system administrator can get a grasp of the component configuration, number of mounted units, Mode switch state, and field replaceable units (FRUs).
Component Information
Table 11-2 lists information of each component of the SPARC M12. You can check the component details in a hierarchical structure by executing the showhardconf command.
Table 11-2  Information of Each Component of the SPARC M12
Component Description
System information Serial number, mode switch status, system power status, system power phase, physical partition status
SPARC M12-2/M12-2S information Unit number, status, role, version, serial number, FRU number, input power type, memory capacity
The role appears as Master, Standby, or Slave.
CPU memory unit (lower)
(CMUL) information
(SPARC M12-2/M12-2S)
Status, version, serial number, FRU number, memory capacity, type
CPU memory unit (upper)
(CMUU) information
(SPARC M12-2/M12-2S)
Status, version, serial number, FRU number, memory capacity, type
Motherboard unit
(MBU) information
(SPARC M12-1)
Status, version, serial number, FRU number, memory capacity, type
CPU information Unit number, status, version, serial number, CPU operating frequency, CPU type, number of CPU cores, number of CPU strands
Memory (MEM) information Unit number, status, code, type (unique ID), capacity
PCI information Unit number, status, name property, vendor ID, device ID, subsystem vendor ID, subsystem ID, VPD number, connection, PCI expansion unit information
PCI expansion unit (PCIBOX) information Unit number, status, version, serial number, FRU number
IO board (IOB) information: Status, serial number, type, FRU number
Link board information: Status, version, serial number, FRU number
PCI information: Unit number, name property, vendor ID, device ID, subsystem vendor ID, subsystem ID, VPD number
Fan backplane (FANBP) information: Unit number, status, serial number, FRU number
PSU backplane (PSUBP) information: Unit number, status, serial number, FRU number
Power supply unit (PSU) information: Unit number, status, serial number, FRU number
Fan unit (FAN) information: Unit number, status
Crossbar unit (XBU) information
(SPARC M12-2/M12-2S)
Unit number, status, version, serial number, FRU number, type
Crossbar cable (CBL) information Unit number, status, vendor ID, version, cable type, length
XSCF unit (XSCFU) information Status, version, serial number, FRU number, type
Operation panel (OPNL) information Status, version, serial number, FRU number, type
PSU backplane (PSUBP) information Status, version, serial number, FRU number, type
Power supply unit (PSU) information Unit number, status, serial number, FRU number, power state, power supply type, voltage, type
The power supply type is AC (alternating current).
Fan unit (FANU) information Unit number, status, type
HDD backplane (HDDBP) information Unit number, status, type
Crossbar box (XBBOX) information
(SPARC M12-2S)
Unit number, status, role, version, serial number, FRU number, input power type
Crossbar unit (XBU) information: Unit number, status, version, serial number, FRU number, type
Crossbar cable (CBL) information: Unit number, status, FRU number, version, cable type, length
XSCF unit (XSCFU) information: Status, version, serial number, FRU number
Operation panel (OPNL) information: Status, version, serial number, FRU number
Crossbar backplane (XBBPU) information: Status, version, serial number, FRU number, type
XSCF interface unit (XSCFIFU) information: Status, version, serial number, FRU number, type
Table 11-3 lists information of each component of the SPARC M10. You can check the component details in a hierarchical structure by executing the showhardconf command.
Table 11-3  Information of Each Component of the SPARC M10
Component Description
System information Serial number, mode switch status, system power status, system power phase, physical partition status
SPARC M10-4/M10-4S information Unit number, status, role, version, serial number, FRU number, input power type, memory capacity
The role appears as Master, Standby, or Slave.
CPU memory unit (lower) (CMUL) information
(SPARC M10-4/M10-4S)
Status, version, serial number, FRU number, memory capacity, type
CPU memory unit (upper) (CMUU) information
(SPARC M10-4/M10-4S)
Status, version, serial number, FRU number, memory capacity, type
Motherboard unit (MBU) information
(SPARC M10-1)
Status, version, serial number, FRU number, memory capacity, type
CPU information Unit number, status, version, serial number,
CPU operating frequency, CPU type, number of CPU cores, number of CPU strands
Memory (MEM) information Unit number, status, code, type (unique ID), capacity
PCI information Unit number, status, name property, vendor ID, device ID, subsystem vendor ID, subsystem ID, VPD number, connection, PCI expansion unit information
PCI expansion unit (PCIBOX) information Unit number, status, version, serial number, FRU number
IO board (IOB) information: Status, serial number, type, FRU number
Link board information: Version, serial number, FRU number
PCI information: Unit number, name property, vendor ID, device ID, subsystem vendor ID, subsystem ID, VPD number
Fan backplane (FANBP) information: Unit number, status, serial number, FRU number
PSU backplane (PSUBP) information: Unit number, status, serial number, FRU number
Power supply unit (PSU) information: Unit number, status, serial number, FRU number
Fan unit (FAN) information: Unit number, status
Crossbar unit (XBU) information
(SPARC M10-4/M10-4S)
Unit number, status, version, serial number, FRU number, type
Crossbar cable (CBL) information Unit number, status, FRU number, version, cable type, length
Operation panel (OPNL) information Status, version, serial number, FRU number
XSCF unit (XSCFU) information Status, version, serial number, FRU number
PSU backplane (PSUBP) information Status, version, serial number, FRU number, type
Power supply unit (PSU) information Unit number, status, serial number, FRU number, power state, power supply type, voltage, type
The displayed power supply type is AC (alternating current) or DC (direct current).
Fan unit (FANU) information Unit number, status, type
Crossbar box (XBBOX) information
(SPARC M10-4S)
Unit number, status, role, version, serial number, FRU number, input power type
Crossbar unit (XBU) information: Unit number, status, version, serial number, FRU number, type
Crossbar cable (CBL) information: Unit number, status, FRU number, version, cable type, length
XSCF unit (XSCFU) information: Status, version, serial number, FRU number
Operation panel (OPNL) information: Status, version, serial number, FRU number
Crossbar backplane (XBBPU) information: Status, version, serial number, FRU number, type
XSCF interface unit (XSCFIFU) information: Status, version, serial number, FRU number, type
Operation Procedure
  1. Execute the showhardconf command to check the component configuration and Mode switch state.
    The following example displays the SPARC M10-1 system.
XSCF> showhardconf
SPARC M10-1;
+ Serial:2101151008A; Operator_Panel_Switch:Locked;
+ System_Power:On; System_Phase:Cabinet Power On;
Partition#0 PPAR_Status:Powered Off;
MBU Status:Normal; Ver:0101h; Serial:7867000297;
+ FRU-Part-Number:CA20393-B50X A2 ;
+ Power_Supply_System:Single;
+ Memory_Size:16 GB;
CPU#0 Status:Normal; Ver:0201h; Serial:PP0629L068
+ Freq:2.800 GHz; Type:32;
+ Core:16; Strand:2;
MEM#00A Status:Normal;
:
  1. Execute the showhardconf command to check the number of mounted FRUs.
    In the following example, the -u option is specified to display the number of FRUs mounted in the SPARC M10-1 system.
XSCF> showhardconf -u
SPARC M10-1; Memory_Size:16 GB;
+-----------------------------------+------------+
| FRU | Quantity |
+-----------------------------------+------------+
| MBU | 1 |
| CPU | 1 |
| Freq:2.800 GHz; | ( 1) |
| MEM | 16 |
| Type:01; Size:4 GB; | ( 16) |
| PCIBOX | 1 |
| IOB | 1 |
| PSU | 2 |
| FAN | 2 |
| OPNL | 1 |
| PSUBP | 1 |
| PSU | 2 |
| FAN_A | 2 |
+-----------------------------------+------------+