11.1.2 Checking Mounted Components in the System
11.1.2 Checking Mounted Components in the System
You can check all the mounted components in the system and their status by using the showhardconf command. The command displays an asterisk (*) to mark a part that has a problem. The system administrator can get a grasp of the component configuration, number of mounted units, Mode switch state, and field replaceable units (FRUs).
Component Information
Table 11-2 lists information of each component of the SPARC M12. You can check the component details in a hierarchical structure by executing the showhardconf command.
Component | Description |
---|---|
System information | Serial number, mode switch status, system power status, system power phase, physical partition status |
SPARC M12-2/M12-2S information | Unit number, status, role, version, serial number, FRU number, input power type, memory capacity The role appears as Master, Standby, or Slave. |
CPU memory unit (lower) (CMUL) information (SPARC M12-2/M12-2S) |
Status, version, serial number, FRU number, memory capacity, type |
CPU memory unit (upper) (CMUU) information (SPARC M12-2/M12-2S) |
Status, version, serial number, FRU number, memory capacity, type |
Motherboard unit (MBU) information (SPARC M12-1) |
Status, version, serial number, FRU number, memory capacity, type |
CPU information | Unit number, status, version, serial number, CPU operating frequency, CPU type, number of CPU cores, number of CPU strands |
Memory (MEM) information | Unit number, status, code, type (unique ID), capacity |
PCI information | Unit number, status, name property, vendor ID, device ID, subsystem vendor ID, subsystem ID, VPD number, connection, PCI expansion unit information |
PCI expansion unit (PCIBOX) information | Unit number, status, version, serial number, FRU number IO board (IOB) information: Status, serial number, type, FRU number Link board information: Status, version, serial number, FRU number PCI information: Unit number, name property, vendor ID, device ID, subsystem vendor ID, subsystem ID, VPD number Fan backplane (FANBP) information: Unit number, status, serial number, FRU number PSU backplane (PSUBP) information: Unit number, status, serial number, FRU number Power supply unit (PSU) information: Unit number, status, serial number, FRU number Fan unit (FAN) information: Unit number, status |
Crossbar unit (XBU) information (SPARC M12-2/M12-2S) |
Unit number, status, version, serial number, FRU number, type |
Crossbar cable (CBL) information | Unit number, status, vendor ID, version, cable type, length |
XSCF unit (XSCFU) information | Status, version, serial number, FRU number, type |
Operation panel (OPNL) information | Status, version, serial number, FRU number, type |
PSU backplane (PSUBP) information | Status, version, serial number, FRU number, type |
Power supply unit (PSU) information | Unit number, status, serial number, FRU number, power state, power supply type, voltage, type The power supply type is AC (alternating current). |
Fan unit (FANU) information | Unit number, status, type |
HDD backplane (HDDBP) information | Unit number, status, type |
Crossbar box (XBBOX) information (SPARC M12-2S) |
Unit number, status, role, version, serial number, FRU number, input power type Crossbar unit (XBU) information: Unit number, status, version, serial number, FRU number, type Crossbar cable (CBL) information: Unit number, status, FRU number, version, cable type, length XSCF unit (XSCFU) information: Status, version, serial number, FRU number Operation panel (OPNL) information: Status, version, serial number, FRU number Crossbar backplane (XBBPU) information: Status, version, serial number, FRU number, type XSCF interface unit (XSCFIFU) information: Status, version, serial number, FRU number, type |
Table 11-3 lists information of each component of the SPARC M10. You can check the component details in a hierarchical structure by executing the showhardconf command.
Component | Description |
---|---|
System information | Serial number, mode switch status, system power status, system power phase, physical partition status |
SPARC M10-4/M10-4S information | Unit number, status, role, version, serial number, FRU number, input power type, memory capacity The role appears as Master, Standby, or Slave. |
CPU memory unit (lower) (CMUL) information (SPARC M10-4/M10-4S) |
Status, version, serial number, FRU number, memory capacity, type |
CPU memory unit (upper) (CMUU) information (SPARC M10-4/M10-4S) |
Status, version, serial number, FRU number, memory capacity, type |
Motherboard unit (MBU) information (SPARC M10-1) |
Status, version, serial number, FRU number, memory capacity, type |
CPU information | Unit number, status, version, serial number, CPU operating frequency, CPU type, number of CPU cores, number of CPU strands |
Memory (MEM) information | Unit number, status, code, type (unique ID), capacity |
PCI information | Unit number, status, name property, vendor ID, device ID, subsystem vendor ID, subsystem ID, VPD number, connection, PCI expansion unit information |
PCI expansion unit (PCIBOX) information | Unit number, status, version, serial number, FRU number IO board (IOB) information: Status, serial number, type, FRU number Link board information: Version, serial number, FRU number PCI information: Unit number, name property, vendor ID, device ID, subsystem vendor ID, subsystem ID, VPD number Fan backplane (FANBP) information: Unit number, status, serial number, FRU number PSU backplane (PSUBP) information: Unit number, status, serial number, FRU number Power supply unit (PSU) information: Unit number, status, serial number, FRU number Fan unit (FAN) information: Unit number, status |
Crossbar unit (XBU) information (SPARC M10-4/M10-4S) |
Unit number, status, version, serial number, FRU number, type |
Crossbar cable (CBL) information | Unit number, status, FRU number, version, cable type, length |
Operation panel (OPNL) information | Status, version, serial number, FRU number |
XSCF unit (XSCFU) information | Status, version, serial number, FRU number |
PSU backplane (PSUBP) information | Status, version, serial number, FRU number, type |
Power supply unit (PSU) information | Unit number, status, serial number, FRU number, power state, power supply type, voltage, type The displayed power supply type is AC (alternating current) or DC (direct current). |
Fan unit (FANU) information | Unit number, status, type |
Crossbar box (XBBOX) information (SPARC M10-4S) |
Unit number, status, role, version, serial number, FRU number, input power type Crossbar unit (XBU) information: Unit number, status, version, serial number, FRU number, type Crossbar cable (CBL) information: Unit number, status, FRU number, version, cable type, length XSCF unit (XSCFU) information: Status, version, serial number, FRU number Operation panel (OPNL) information: Status, version, serial number, FRU number Crossbar backplane (XBBPU) information: Status, version, serial number, FRU number, type XSCF interface unit (XSCFIFU) information: Status, version, serial number, FRU number, type |
Operation Procedure
- Execute the showhardconf command to check the component configuration and Mode switch state.
The following example displays the SPARC M10-1 system.
XSCF> showhardconf SPARC M10-1; + Serial:2101151008A; Operator_Panel_Switch:Locked; + System_Power:On; System_Phase:Cabinet Power On; Partition#0 PPAR_Status:Powered Off; MBU Status:Normal; Ver:0101h; Serial:7867000297; + FRU-Part-Number:CA20393-B50X A2 ; + Power_Supply_System:Single; + Memory_Size:16 GB; CPU#0 Status:Normal; Ver:0201h; Serial:PP0629L068 + Freq:2.800 GHz; Type:32; + Core:16; Strand:2; MEM#00A Status:Normal; : |
- Execute the showhardconf command to check the number of mounted FRUs.
In the following example, the -u option is specified to display the number of FRUs mounted in the SPARC M10-1 system.
XSCF> showhardconf -u SPARC M10-1; Memory_Size:16 GB; +-----------------------------------+------------+ | FRU | Quantity | +-----------------------------------+------------+ | MBU | 1 | | CPU | 1 | | Freq:2.800 GHz; | ( 1) | | MEM | 16 | | Type:01; Size:4 GB; | ( 16) | | PCIBOX | 1 | | IOB | 1 | | PSU | 2 | | FAN | 2 | | OPNL | 1 | | PSUBP | 1 | | PSU | 2 | | FAN_A | 2 | +-----------------------------------+------------+ |
< Previous Page | Next Page >