Skip to main content

10.10.2 Saving XSCF Settings Information


10.10.2 Saving XSCF Settings Information
This section describes the procedure for saving the XSCF configuration file.
Note - With the dumpconfig command, the XSCF settings information can be encrypted and saved. For details, see the dumpconfig(8) command man page or the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 XSCF Reference Manual.
Saving the Setting Information to a USB Device on the Master XSCF
  1. Connect a USB device to a USB port on the XSCF unit panel (rear panel) of the master XSCF.
  2. Specify the name of the output file for the local USB device on the XSCF, and execute the dumpconfig command.
XSCF> dumpconfig file:///media/usb_msd/backup-file.txt
  1. Remove the USB device from the USB port when the data transfer has completed.
  2. Confirm the identification information at the beginning of the configuration file that was saved.
Specifying the Target Directory and Saving the Setting Information via a Network
  1. Specify the target directory and the output file name, and execute the dumpconfig command.
XSCF> dumpconfig ftp://server/backup/backup-sca-ff2-16.txt
:
  1. Confirm the identification information at the beginning of the saved configuration file when the data transfer has completed.
Configuration File Format
The saved configuration file has the following format:
  1. - File name: User-specified name
  2. - File format: base64 encoded text