10.10.2 Saving XSCF Settings Information
10.10.2 Saving XSCF Settings Information
This section describes the procedure for saving the XSCF configuration file.
Note - With the dumpconfig command, the XSCF settings information can be encrypted and saved. For details, see the dumpconfig(8) command man page or the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 XSCF Reference Manual. |
Saving the Setting Information to a USB Device on the Master XSCF
- Connect a USB device to a USB port on the XSCF unit panel (rear panel) of the master XSCF.
- Specify the name of the output file for the local USB device on the XSCF, and execute the dumpconfig command.
XSCF> dumpconfig file:///media/usb_msd/backup-file.txt |
- Remove the USB device from the USB port when the data transfer has completed.
- Confirm the identification information at the beginning of the configuration file that was saved.
Specifying the Target Directory and Saving the Setting Information via a Network
- Specify the target directory and the output file name, and execute the dumpconfig command.
XSCF> dumpconfig ftp://server/backup/backup-sca-ff2-16.txt : |
- Confirm the identification information at the beginning of the saved configuration file when the data transfer has completed.
Configuration File Format
The saved configuration file has the following format:
- - File name: User-specified name
- - File format: base64 encoded text
< Previous Page | Next Page >