4.3.3 Checking the Dual Power Feed Setting
4.3.3 Checking the Dual Power Feed Setting
Use the showdualpowerfeed command of the XSCF firmware to check the dual power feed setting.
XSCF> showdualpowerfeed |
The output is any of the following, depending on the status.
- Output when dual power feed is enabled
BB#00: Dual power feed is enabled. |
- Output when dual power feed is disabled
BB#00: Dual power feed is disabled. |
- Output when dual power feed was changed from enabled to disabled
BB#00:enable -> disable NOTE: Dual power feed will be change the next time the platform is powered on. |
- Output when dual power feed was changed from disabled to enabled
BB#00:disable -> enable NOTE: Dual power feed will be change the next time the platform is powered on. |
Operation Procedure
- Check the dual power feed setting with the showdualpowerfeed command.
In the following example, you can see a change from disabled to enabled in a system configuration with BB-ID 0 and BB-ID 1.
XSCF> showdualpowerfeed BB#00:disable -> enable BB#01:disable -> enable NOTE: Dual power feed will be change the next time the platform is powered on. |