6.8.2 Starting the system from the operation panel
6.8.2 Starting the system from the operation panel
- Check that the XSCF STANDBY LED on the operation panel is on.
- Press the power switch on the operation panel for 1 second or more (less than 4 seconds).
For details, see "2.3.2 Control function of the operation panel."
Note - For a building block configuration, press the power switch on the master chassis. The power switches of the other chassis are disabled. |
- Confirm that the POWER LED on the operation panel is on.
- Execute the showpparstatus command to confirm that the power to all the physical partitions in the system is turned on.
- Confirm that no error remains by using the fmadm faulty command in the logical domain in which an error was detected.
# fmadm faulty |
- If any error remains, clear the error by using the fmadm repaired command.