Skip to main content

16.3 Removing an XSCF BB Control Cable


16.3 Removing an XSCF BB Control Cable
This section describes the procedure for removing the XSCF BB control cables.
Enable removal of the XSCF BB control cables before attempting to remove them. For details, see "Chapter 7 Maintenance Flow."
Caution - Before you handle the XSCF BB control cables, wear a wrist strap to ground any static electricity. If you perform this procedure without a wrist strap, individual components or the overall system may be damaged. For details, see "1.5 Precautions on Static Electricity."
  1. Remove the XSCF BB control cable from the SPARC M10-4S or the crossbar box.
    Pull out an XSCF BB control cable while pushing the lock release buttons (A in the figure) on the both sides of the cable.
Note - The cables on the rear of the crossbar box are bundled together and fastened to the right-hand cable support with a hook-and-loop fastener. When removing the XSCF BB control cables, remove the hook-and-loop fastener from the cable support.
Figure 16-3  Removing the XSCF BB control cables (SPARC M10-4S)
Figure 16-3  Removing the XSCF BB control cables (SPARC M10-4S)
Figure 16-4  Removing the XSCF BB control cables (crossbar box)
Figure 16-4  Removing the XSCF BB control cables (crossbar box)
  1. Remove the XSCF BB control cables from the other chassis.
    Pull out an XSCF BB control cable while pushing the lock release buttons on the both sides of the cable.