Skip to main content

4.1.1 Confirming the hardware configuration


4.1.1 Confirming the hardware configuration
Execute the showhardconf command to confirm the configuration and status of the FRU mounted in the chassis. Also confirm the hardware RAID volume.
Before performing any maintenance work, check and record the hardware configuration of the chassis.
  1. Log in to the XSCF shell.
  2. Execute the showhardconf command to check the hardware configuration information.
The following information appears:
  1. Current configuration and status
  2. Number of mounted FRUs
  3. Status of the unit in which a physical partition error or degradation occurred
  4. Information on the PCI expansion unit
  5. Name properties of the PCI Express (PCIe) card
The following is an execution example of the showhardconf command.
XSCF> showhardconf -M
SPARC M10-4 ;
+ Serial:2081230012; Operator_Panel_Switch:Service;
+ System_Power:Off; System_Phase:Cabinet Power Off;
BB#00 Status:Normal; Role:Master; Ver:2209h; Serial:2081231002;
+ FRU-Part-Number:CA07361-D203 A2 /9999999 ;
+ Power_Supply_System:Single;
+ Memory_Size:512 GB;
CMUL Status:Normal; Ver:0301h; Serial:PP140601D9 ;
+ FRU-Part-Number:CA07361-D251 A4 /9999999 ;
+ Memory_Size:256 GB; Type: B ; (*1)
CPU#0 Status:Normal; Ver:4142h; Serial:00020203;
+ Freq:3.200 GHz; Type:0x20; (*2)
+ Core:16; Strand:2; (*3)
(Omitted)
*1 Type: B is displayed for a CMU that has the SPARC64 X+ processor mounted. Type: A is displayed for a CMU that has the SPARC64 X processor mounted.
*2 If the SPARC64 X+ processor is mounted, 3.200 GHz or 3.700 GHz; Type:0x20 is displayed. If the SPARC64 X processor is mounted, 3.000 GHz; Type:0x10 is displayed.
*3 If the SPARC64 X+ (3.7 GHz (eight-core)) processor is mounted, "Core:8" is displayed.
  1. Check the hardware RAID volume.
    To use the hardware RAID function installed in the SPARC M10-4/M10-4S to check the configuration and status of the hardware RAID volume, log in to Oracle Solaris on the control domain or root domain. Check the contents displayed by the sas2ircu command of the SAS-2 Integrated RAID Configuration Utility (referred to below as the SAS2IRCU utility).
  1. Before performing hardware RAID volume maintenance, be sure to write down the information on hardware RAID settings and the information on the HDD/SSD components of the RAID volume.
  1. For details on how to obtain the SAS2IRCU utility and the user guide, see "Obtaining SAS-2 Integrated RAID Configuration Utility" in the latest version of the Fujitsu M10/SPARC M10 Systems Product Notes.
  1. The following is an example of what the sas2ircu command displays.
root# ./sas2ircu 0 display
LSI Corporation SAS2 IR Configuration Utility.
Version 19.00.00.00 (2014.03.17)
Copyright (c) 2008-2014 LSI Corporation. All rights reserved.
Read configuration has been initiated for controller 0
------------------------------------------------------------------------

Controller information (*1)
------------------------------------------------------------------------

Controller type : SAS2308_2
BIOS version : 0.00.00.00
Firmware version : 13.00.66.00
Channel description : 1 Serial Attached SCSI
Initiator ID : 0
Maximum physical devices : 255
Concurrent commands supported : 3072
Slot : Unknown
Segment : 0
Bus : 3
Device : 0
Function : 0
RAID Support : Yes
------------------------------------------------------------------------

IR Volume information (*2)
------------------------------------------------------------------------

IR volume 1
Volume ID : 285
Volume Name : raid10
Status of volume : Okay (OKY)
Volume wwid : 0bff050b918f7d4d
RAID level : RAID10
Size (in MB) : 1713750
Physical hard disks :
PHY[0] Enclosure#/Slot# : 2:2
PHY[1] Enclosure#/Slot# : 2:3
PHY[2] Enclosure#/Slot# : 2:4
PHY[3] Enclosure#/Slot# : 2:5
PHY[4] Enclosure#/Slot# : 2:6
PHY[5] Enclosure#/Slot# : 2:7
IR volume 2
Volume ID : 286
Volume Name : 0
Status of volume : Okay (OKY)
Volume wwid : 01a0a262cfe15e62
RAID level : RAID1
Size (in MB) : 571250
Physical hard disks :
PHY[0] Enclosure#/Slot# : 2:0
PHY[1] Enclosure#/Slot# : 2:1
------------------------------------------------------------------------

Physical device information (*3)
------------------------------------------------------------------------

Initiator at ID #0
Device is a Enclosure services device
Enclosure # : 2
Slot # : 0
SAS Address : 500000e-0-e06d-307d
State : Standby (SBY)
Manufacturer : FUJITSU
Model Number : BBEXP
Firmware Revision : 0d32
Serial No : x3625413500
GUID : N/A
Protocol : SAS
Device Type : Enclosure services device
Device is a Hard disk
Enclosure # : 2
Slot # : 0
SAS Address : 5000039-7-584a-dada
State : Optimal (OPT)
Size (in MB)/(in sectors) : 572325/1172123567
Manufacturer : TOSHIBA
Model Number : AL13SEB600AL14SE
Firmware Revision : 3703
Serial No : X6N0A01PF7TD
GUID : 50000397584adad9
Protocol : SAS
Drive Type : SAS_HDD
Device is a Hard disk
Enclosure # : 2
Slot # : 1
SAS Address : 5000039-7-0830-e08a
State : Optimal (OPT)
Size (in MB)/(in sectors) : 572325/1172123567
Manufacturer : TOSHIBA
Model Number : AL13SEB600AL14SE
Firmware Revision : 3702
Serial No : 56F0A08HF7TD
GUID : 500003970830e089
Protocol : SAS
Drive Type : SAS_HDD
Device is a Hard disk
Enclosure # : 2
Slot # : 2
SAS Address : 5000039-4-281b-4eaa
State : Optimal (OPT)
Size (in MB)/(in sectors) : 572325/1172123567
Manufacturer : TOSHIBA
Model Number : MBF2600RC
Firmware Revision : 3706
Serial No : EA25PC7007KR
GUID : 50000394281b4ea8
Protocol : SAS
Drive Type : SAS_HDD
Device is a Hard disk
Enclosure # : 2
Slot # : 3
SAS Address : 5000039-4-281a-9072
State : Optimal (OPT)
Size (in MB)/(in sectors) : 572325/1172123567
Manufacturer : TOSHIBA
Model Number : MBF2600RC
Firmware Revision : 3706
Serial No : EA25PC7007GR
GUID : 50000394281a9070
Protocol : SAS
Drive Type : SAS_HDD
Device is a Hard disk
Enclosure # : 2
Slot # : 4
SAS Address : 5000039-4-6810-716e
State : Optimal (OPT)
Size (in MB)/(in sectors) : 572325/1172123567
Manufacturer : TOSHIBA
Model Number : MBF2600RC
Firmware Revision : 3706
Serial No : EA25PCB009C6
GUID : 500003946810716c
Protocol : SAS
Drive Type : SAS_HDD
Device is a Hard disk
Enclosure # : 2
Slot # : 5
SAS Address : 5000039-4-7811-a90a
State : Optimal (OPT)
Size (in MB)/(in sectors) : 572325/1172123567
Manufacturer : TOSHIBA
Model Number : MBF2600RC
Firmware Revision : 3706
Serial No : EA25PCC00A9L
GUID : 500003947811a908
Protocol : SAS
Drive Type : SAS_HDD
Device is a Hard disk
Enclosure # : 2
Slot # : 6
SAS Address : 5000039-4-0820-09fe
State : Optimal (OPT)
Size (in MB)/(in sectors) : 572325/1172123567
Manufacturer : TOSHIBA
Model Number : MBF2600RC
Firmware Revision : 3706
Serial No : EA25PC50077P
GUID : 50000394082009fc
Protocol : SAS
Drive Type : SAS_HDD
Device is a Hard disk
Enclosure # : 2
Slot # : 7
SAS Address : 5000039-4-8822-6226
State : Optimal (OPT)
Size (in MB)/(in sectors) : 572325/1172123567
Manufacturer : TOSHIBA
Model Number : MBF2600RC
Firmware Revision : 3706
Serial No : EA25PD100AVW
GUID : 5000039488226224
Protocol : SAS
Drive Type : SAS_HDD
------------------------------------------------------------------------

Enclosure information (*4)
------------------------------------------------------------------------

Enclosure# : 1
Logical ID : 500000e0:e0450000
Numslots : 8
StartSlot : 0
Enclosure# : 2
Logical ID : 500000e0:e06d307f
Numslots : 9
StartSlot : 0
------------------------------------------------------------------------

SAS2IRCU: Command DISPLAY Completed Successfully.
SAS2IRCU: Utility Completed Successfully.
*1 SAS controller information
*2 RAID volume information
*3 Physical device information
*4 Information about the body of the SPARC M10 server