3.3 Inactive Maintenance
3.3 Inactive Maintenance
The type of maintenance performed with the physical partition stopped--the one to which the chassis requiring maintenance belongs--is referred to as inactive maintenance. You can perform inactive maintenance only for a system that uses the SPARC M10-4S in a building block configuration.
Table 3-4 shows whether inactive maintenance is enabled for each FRU.
-: Maintenance cannot be performed. |
||
---|---|---|
FRU | Building block configuration | |
Inactive/hot maintenance | Inactive/cold maintenance | |
CPU memory unit | - | OK |
Memory | - | OK |
Crossbar unit | - | OK |
Power supply unit | OK | OK |
Fan unit | OK | OK |
Internal disk | OK | OK |
PCIe card | OK | OK |
PSU backplane unit | - | OK |
Operation panel | - | OK |
Crossbar cable | - | OK |
XSCF BB control cable | - | OK |
XSCF DUAL control cable | - | OK |
< Previous Page | Next Page >