6.2.1 Incorporation of the SPARC M10-4S chassis (possible only in a system with a building block configuration)


6.2.1 Incorporation of the SPARC M10-4S chassis (possible only in a system with a building block configuration)
This section describes the procedure for incorporating a FRU into the system after maintenance.
  1. After completing maintenance of the target FRU, return to the replacefru command operation of the XSCF firmware, and enter "f".
Please execute the following steps:
1) Confirm the XSCF STANDBY LED of BB#0 is not lit.
2) Turn off the breaker of BB#0.
3) Remove BB#0.
4) Execute either the following:
4-1) After the exchanged device is connected with the system,
turn on the breaker of BB#0, and please select 'finish'.
4-2) If you want to suspend the maintenance without exchanging device,
please select 'cancel'.
[f:finish|c:cancel] :f
  1. Entering "f" displays the following screen. Wait until the processing has completed.
Waiting for BB#0 to enter install state.
[This operation may take up to 20 minute(s)]
(progress scale reported in seconds)
0..... 30..... 60..... 90..... 120..... 150..... 180..... 210.....
240..... 270..... 300..... 330..... 360..... done


Waiting for BB#0 to enter ready state.
[This operation may take up to 45 minute(s)]
(progress scale reported in seconds)
0..... 30..... 60..... 90..... 120..... 150..... 180..... 210.....
240..... 270..... 300..... done


Do you want to start to diagnose BB#0?[s:start|c:cancel] :
  1. After confirming that the FRU to be diagnosed is displayed, enter "s".
Do you want to start to diagnose BB#0?[s:start|c:cancel] :s
Note - If you are replacing the PCI Express card or internal disk, enter "c" to cancel the SPARC M10-4S diagnosis. After finishing the steps described in this section, see "6.3.1 Diagnosing the system board," and perform a diagnosis by executing the testsb command with the -v, -p, or -s option specified.
  1. After confirming again that the FRU to be diagnosed is displayed, enter "y".
Diagnostic tests for BB#0 have started.
Initial diagnosis is about to start, Continue?[y|n] :y
  1. The following screen is displayed. Wait until the processing has completed.
PSB#00-0 power on sequence started.
0....end
Initial diagnosis started. [7200sec]
0..... 30..... 60..... 90.....120.....150.....180.....210.....240...../
270.....300.....330.....360.....390.....420.....450.....480.....510.....-

540.end

Initial diagnosis has completed.
PSB power off sequence started. [1200sec]
0..... 30.....end
PSB powered off.
PSB Test Fault
---- ------- --------

00-0 Passed Normal
done
  1. Confirm that the status is normal ("Normal") after the replacement, and then enter "f".
------------------------------------------------------------------------------

Maintenance/Replacement Menu
Status of the replaced FRU.

FRU Status
------------------- --------------

/BB#0 Normal
------------------------------------------------------------------------------

The replacement of BB#0 has completed normally.[f:finish] :f
  1. When the maintenance menu appears, enter "c" to exit the operation.
------------------------------------------------------------------------------

Maintenance/Replacement Menu
Please select the chassis including replaced FRU.
No. FRU Status
--- ------------------- --------------

1 /BB#0 Normal

2 /BB#1 Normal

3 /BB#2 Normal

4 /BB#3 Normal

------------------------------------------------------------------------------

Select [1-4|c:cancel] :c