3.4 System-stopped Maintenance


3.4 System-stopped Maintenance
The type of maintenance performed with all physical partitions on the system stopped is referred to as system-stopped maintenance.
Table 3-5 shows whether system-stopped maintenance is enabled for each FRU.
Table 3-5  Whether system-stopped maintenance (replacement/addition/removal) is enabled for each FRU
-: Maintenance cannot be performed.
FRU Single-chassis configuration Building block configuration
System-stopped/hot maintenance System-stopped/cold maintenance System-stopped/hot maintenance System-stopped/cold maintenance System-stopped/all power-off cold maintenance
CPU memory unit - OK - OK OK
Memory - OK - OK
OK
Crossbar unit (*1) - OK - OK OK
Power supply unit OK OK OK OK OK
Fan unit OK OK OK OK OK
Internal disk OK OK OK OK OK
PCIe card OK OK OK OK OK
PSU backplane unit - OK - OK OK
Operation panel - OK - OK OK
Crossbar cable (*2) - - - OK OK
XSCF BB control cable (*2) - - - OK OK
XSCF DUAL control cable (*2) - - - OK OK
*1 The unit is mounted only in the SPARC M10-4S.
*2 The cable is mounted only in a building block configuration using the SPARC M10-4S.