3.4 System-stopped Maintenance
3.4 System-stopped Maintenance
The type of maintenance performed with all physical partitions on the system stopped is referred to as system-stopped maintenance.
Table 3-5 shows whether system-stopped maintenance is enabled for each FRU.
-: Maintenance cannot be performed. |
|||||
---|---|---|---|---|---|
FRU | Single-chassis configuration | Building block configuration | |||
System-stopped/hot maintenance | System-stopped/cold maintenance | System-stopped/hot maintenance | System-stopped/cold maintenance | System-stopped/all power-off cold maintenance | |
CPU memory unit | - | OK | - | OK | OK |
Memory | - | OK | - | OK |
OK |
Crossbar unit (*1) | - | OK | - | OK | OK |
Power supply unit | OK | OK | OK | OK | OK |
Fan unit | OK | OK | OK | OK | OK |
Internal disk | OK | OK | OK | OK | OK |
PCIe card | OK | OK | OK | OK | OK |
PSU backplane unit | - | OK | - | OK | OK |
Operation panel | - | OK | - | OK | OK |
Crossbar cable (*2) | - | - | - | OK | OK |
XSCF BB control cable (*2) | - | - | - | OK | OK |
XSCF DUAL control cable (*2) | - | - | - | OK | OK |
*1 The unit is mounted only in the SPARC M10-4S. *2 The cable is mounted only in a building block configuration using the SPARC M10-4S. |
< Previous Page | Next Page >