A.2.1 Checking the component status
A.2.1 Checking the component status
Use the showhardconf command to check the status of each field replaceable unit (FRU). The displayed information is as follows:
- Current configuration and status
- Quantities of mounted FRUs by FRU type, such as CPU, memory, and PCIe card
- Physical partition (PPAR) information
- PCI expansion unit information (displayed only when the power to the physical partition is on)
- PCIe card information (displayed only when the power to the physical partition is on)
showhardconf command
Use the showhardconf command to check the system hardware configuration and the status of each component.
A displayed asterisk (*) indicates the fault location regarding a unit where a failure or degradation occurred.
Status displays the following statuses.
A displayed asterisk (*) indicates the fault location regarding a unit where a failure or degradation occurred.
Status displays the following statuses.
- Faulted: Non-operational status of the relevant component due to failure
- Degraded: A part of the unit has failed, but the unit continues in operation.
- Deconfigured: The unit including its components on the lower layers is in a normal condition, but it has been degraded due to the influence of a failure or degradation of another unit.
- Maintenance: Maintenance work in progress. The addfru command, replacefru command, or initbb command is in operation.
- Normal: Normal status
Example: SPARC M10-4S display example
XSCF> showhardconf -M SPARC M10-4S; + Serial:20xxxxxxxx; Operator_Panel_Switch:Locked; * System serial number + System_Power:On; System_Phase:Cabinet Power On; Partition#0 PPAR_Status:Powered Off; Partition#1 PPAR_Status:Initialization Phase; BB#00 Status:Normal; Role:Standby; Ver:2003h; Serial:2081231002; * Chassis serial number + FRU-Part-Number:CA07361-D203 B0 /9999999 ; + Power_Supply_System: ; + Memory_Size:512 GB; CMUL Status:Normal; Ver:0301h; Serial:PP140601D9 ; + FRU-Part-Number:CA07361-D251 A4 /9999999 ; + Memory_Size:256 GB; Type: B ; CPU#0 Status:Normal; Ver:4142h; Serial:00020203; + Freq:3.700 GHz; Type:0x20; + Core:16; Strand:2; CPU#1 Status:Normal; Ver:4142h; Serial:00020199; + Freq:3.700 GHz; Type:0x20; + Core:16; Strand:2; MEM#00A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CD95; + Type:07; Size:16 GB; MEM#01A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CD9C; + Type:07; Size:16 GB; MEM#02A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CDB4; + Type:07; Size:16 GB; MEM#03A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CDA6; + Type:07; Size:16 GB; MEM#04A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CD9D; + Type:07; Size:16 GB; MEM#05A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CD91; + Type:07; Size:16 GB; MEM#06A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CDA7; + Type:07; Size:16 GB; MEM#07A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CDB7; + Type:07; Size:16 GB; MEM#10A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CDB5; + Type:07; Size:16 GB; MEM#11A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CDB8; + Type:07; Size:16 GB; MEM#12A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CD94; + Type:07; Size:16 GB; MEM#13A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CDBD; + Type:07; Size:16 GB; MEM#14A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CDB9; + Type:07; Size:16 GB; MEM#15A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CDBA; + Type:07; Size:16 GB; MEM#16A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CDBC; + Type:07; Size:16 GB; MEM#17A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CDBB; + Type:07; Size:16 GB; CMUU Status:Normal; Ver:0301h; Serial:PP140601DH ; + FRU-Part-Number:CA07361-D271 A3 /9999999 ; + Memory_Size:256 GB; Type: B ; CPU#0 Status:Normal; Ver:4142h; Serial:00030239; + Freq:3.700 GHz; Type:0x20; + Core:16; Strand:2; CPU#1 Status:Normal; Ver:4142h; Serial:00020195; + Freq:3.700 GHz; Type:0x20; + Core:16; Strand:2; MEM#00A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-3837DC35; + Type:07; Size:16 GB; MEM#01A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-3837DC33; + Type:07; Size:16 GB; MEM#02A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CDC9; + Type:07; Size:16 GB; MEM#03A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CD9A; + Type:07; Size:16 GB; MEM#04A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-3837DBE1; + Type:07; Size:16 GB; MEM#05A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-3837DBD6; + Type:07; Size:16 GB; MEM#06A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CD98; + Type:07; Size:16 GB; MEM#07A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CD96; + Type:07; Size:16 GB; MEM#10A Status:Normal; + Code:2c800f36KSF2G72PZ-1G6E2 4532-E229CC88; + Type:07; Size:16 GB; Omitted PCI#0 Status:Normal; Name_Property:; + Vendor-ID:14e4; Device-ID:1648; + Subsystem_Vendor-ID:10cf; Subsystem-ID:13a0; + Model: LPe1250-F8-FJ; PCI#1 Status:Normal; Name_Property:; + Vendor-ID:14e4; Device-ID:1648; + Subsystem_Vendor-ID:10cf; Subsystem-ID:13a0; + Model: LPe1250-F8-FJ; XBU#0 Status:Normal; Ver:0101h; Serial:PP123002ZQ ; + FRU-Part-Number:CA07361-D102 A1 ; XBU#1 Status:Normal; Ver:0101h; Serial:PP123002ZN ; + FRU-Part-Number:CA07361-D102 A1 ; OPNL Status:Normal; Ver:0101h; Serial:PP1230020A ; + FRU-Part-Number:CA07361-D012 A1 ; PSUBP Status:Normal; Ver:0101h; Serial:PP123002ZS ; + FRU-Part-Number:CA07361-D202 A1 ; PSU#0 Status:Normal; Ver:303443h; Serial:MD12190452 ; + FRU-Part-Number:CA01022-0761 / ; + Power_Status:ON; AC:200 V; Type: A ; PSU#1 Status:Normal; Ver:303443h; Serial:MD12190454 ; + FRU-Part-Number:CA01022-0761 / ; + Power_Status:ON; AC:200 V; Type: A ; FANU#0 Status:Normal; FANU#1 Status:Normal; FANU#2 Status:Normal; FANU#3 Status:Normal; FANU#4 Status:Normal; BB#01 Status:Normal; Role:Standby Ver:0101h; Serial:7867000297; * Chassis serial number + FRU-Part-Number:CA20393-B50X A2 ; + Power_Supply_System:Single; + Memory_Size:256 GB; Omitted XBBOX#80 Status:Normal; Role:Master Ver:0101h; Serial:7867000297; * Chassis serial number + FRU-Part-Number:CA07361-D011 A0 /NOT-FIXD-01 ; + Power_Supply_System:Single; XBU#0 Status:Normal; Serial:PP0629L068 + FRU-Part-Number:CA20393-B50X A2 ; XSCFU Status:Normal; Ver:0101h; Serial:7867000262 ; + FRU-Part-Number:CA20393-B56X A0 XBBPU Status:Normal; Serial:PP0629L068 + FRU-Part-Number:CA20393-B50X A2 ; XSCFIFU Status:Normal; Ver:0101h; Serial:PP12040198 ; + FRU-Part-Number:CA20365-B52X 001AA/NOT-FIXD-01 ; Type: A ; OPNL Status:Normal; Serial:PP0629L068 + FRU-Part-Number:CA20393-B50X A2 ; PSU#0 Status:Normal; Ver:0201 Serial:0000000-ASTECB18 ; + FRU-Part-Number:CF00300-1898 0002 /300-1898-00-02; + Power_Status:ON; AC:200 V; |
showhardconf -u command
Use the showhardconf command with the -u option to display the quantity of each type of mounted field replaceable unit.
The CPU modules are displayed with the operating frequency, and the memory units are displayed with the capacity per memory. If the option is omitted, the command displays the current configuration information, status information, and physical partition (PPAR) information for each field replaceable unit.
The CPU modules are displayed with the operating frequency, and the memory units are displayed with the capacity per memory. If the option is omitted, the command displays the current configuration information, status information, and physical partition (PPAR) information for each field replaceable unit.
Example: SPARC M10-4S display example
XSCF> showhardconf -u SPARC M10-4S; Memory_Size:2048 GB; +-----------------------------------+------------+ | FRU | Quantity | +-----------------------------------+------------+ | BB | 2 | | CMUL | 2 | | Type:B | ( 2) | | CPU | 4 | | Freq:3.700 GHz; | ( 4) | | MEM | 64 | | Type:07; Size:16 GB; | ( 64) | | CMUU | 2 | | Type:B | ( 2) | | CPU | 4 | | Freq:3.700 GHz; | ( 4) | | MEM | 64 | | Type:07; Size:16 GB; | ( 64) | | PCICARD | 3 | | LINKCARD | 0 | | PCIBOX | 0 | | IOB | 0 | | LINKBOARD | 0 | | PCI | 0 | | FANBP | 0 | | PSU | 0 | | FAN | 0 | | XBU | 4 | | Type:A | ( 4) | | OPNL | 2 | | PSUBP | 2 | | Type:B | ( 2) | | PSU | 4 | | Type:B | ( 4) | | FAN | 10 | | XBBOX | 0 | | XBU | 0 | | XSCFU | 0 | | OPNL | 0 | | XBBPU | 0 | | XSCFIFU | 0 | | PSU | 0 | | FANU | 0 | +-----------------------------------+------------+ |
< Previous Page | Next Page >