If operation is not normal during installation work, you may wonder whether there was a failure. In such cases, inspect the following items and take corrective measures accordingly.
Table A-1  List of problem case examples
Case Possible cause Corrective action
The input power cannot be turned on. The power cord is disconnected. Connect the power cord correctly.
The breaker on the distribution board is turned off. Turn on the breaker.
The system management terminal does not display the login prompt. The serial cable is not connected to the serial port. Connect the serial cable correctly to the serial port of the chassis.
See Figure 5-1 in "5.1 Connecting Cables to the SPARC M10-4S."
See Figure 5-15 in "5.3 Connecting Cables to a Crossbar Box."
For a building block configuration, connect the serial cable to the serial port of the chassis whose MASTER LED of the XSCF unit is lit.
After the input power is turned on, the MASTER LEDs on all chassis are lit. BB-IDs have not been set. Initialize each chassis to the factory default settings, and change the BB-IDs to the correct settings.
See "A.3.1 BB-IDs not set (BB-ID 00)."
The XCP version check displays only BB#00. BB-IDs have not been set. Initialize each chassis to the factory default settings, and change the BB-IDs to the correct settings.
See "A.3.1 BB-IDs not set (BB-ID 00)."
The XCP version check displays only BB#00 and BB#01 even though the configuration has at least three BBs. The BB-IDs of BB#00 and BB#01 are reversed. Initialize BB#00 and BB#01 to the factory default settings, and change the BB-IDs to the correct settings.
See "A.3.3 Mistaken settings for BB#00 and BB#01."
The XCP version check does not display BB#03 even though the configuration has four BBs. BB#03 has the wrong BB-ID setting. Change the BB-ID to the correct setting.
See "A.3.2 Mistaken setting of a BB-ID other than BB#00 or BB#01."
The component status check (by the showhardconf command) of a building block configuration displays only BB#00. The XSCF cables between chassis are incorrectly connected. Check messages by using the showlogs command.
See "A.2.2 Checking the contents of logs."
"Failed" appears in the results of a diagnosis test performed on a building block configuration. The crossbar cables between chassis are incorrectly connected. Check messages by using the showlogs command.
See "A.2.2 Checking the contents of logs."
The following errors are displayed by the showlogs error command executed in a system with a 3BB configuration or larger:
- BB control cable detected unexpected

- Cannot communicate with the other XSCF
The XSCF BB control cable is not completely in contact, or the cable is faulty. Connect the XSCF BB control cable correctly.
If the error is still displayed after you confirm the connection, replace the cable.