Skip to main content
  1. Home >
  2. Products >
  3. Computing Products >
  4. Servers >
  5. Fujitsu SPARC servers >
  6. Downloads >
  7. User Manuals >
  8. Fujitsu M10-4S/SPARC M10-4S Installation Guide >
  9. 9.5.3 Adding the SPARC M10-4S in the expansion racks

9.5.3 Adding the SPARC M10-4S in the expansion racks


9.5.3 Adding the SPARC M10-4S in the expansion racks
In the expansion rack installed in 9.5.2, mount the SPARC M10-4S that was changed to the 1BB configuration in 9.5.1. Then, perform installation work.
  1. Mount the SPARC M10-4S in the rack.
    For details, see "3.4.1 Mounting the SPARC M10-4S in a rack."
  2. Set the ID required for identifying each chassis (BB-ID).
    For details, see "4.1 Setting the ID (BB-ID) Identifying a Chassis."
  3. Connect the crossbar cables (optical) and XSCF BB control cables to each chassis.
    Crossbar cables (optical) and XSCF BB control cables are already laid in the expansion rack. The work here is to connect the cables to each port of the mounted chassis. Connect the cables according to the instructions written on the labels.
    For details on the connection of the cables that pass between the racks, see "4.3.2 Connecting crossbar cables" and "4.3.1 Connecting XSCF cables."
    For a cable connection diagram and a cable list, see "B.5 9BB Configuration to 16BB Configuration (Connections through Crossbar Boxes)."
  4. Connect serial cables, LAN cables, and power cords to crossbar boxes.
    For details, see "5.3 Connecting Cables to a Crossbar Box."
  5. Connect the system management terminal to the crossbar box of the master XSCF, and then perform an initial diagnosis of the system.
    For details, see "Chapter 6 Performing an Initial System Diagnosis."
  6. Initialize the system settings from the crossbar box of the master XSCF.
    For details, see "Chapter 7 Making the Initial System Settings."
  7. Reconfigure the logical domains.
    Assign the resources of the added SPARC M10-4S to an existing logical domain or a newly configured logical domain. For details, see the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide.