6.8 Checking the Component Status
6.8 Checking the Component Status
This section describes the procedure for checking the configuration, status, and quantities of the mounted field replaceable units (FRUs).
- Execute the showhardconf command.
The command displays all the FRUs mounted in the chassis and their status. However, it does not display the status of I/O-related components such as PCIe cards and PCI expansion units while the system power is off.
- Example: SPARC M10-4S display example
XSCF> showhardconf -M SPARC M10-4S; + Serial:2081230012; Operator_Panel_Switch:Service; + System_Power:Off; System_Phase:Cabinet Power Off; BB#00 Status:Normal; Role:Master; Ver:2209h; Serial:2081231002; + FRU-Part-Number:CA07361-D203 A2 /9999999 ; + Power_Supply_System:Single; + Memory_Size:512 GB; CMUL Status:Normal; Ver:0301h; Serial:PP140601D9 ; + FRU-Part-Number:CA07361-D251 A4 /9999999 ; + Memory_Size:256 GB; Type: B ; (*1) CPU#0 Status:Normal; Ver:4142h; Serial:00020203; + Freq:3.700 GHz; Type:0x20; (*2) + Core:16; Strand:2; Omitted |
*1 For a CMU on which the SPARC64 X+ processor is mounted, "Type: B" is displayed. For a CMU on which the SPARC64 X processor is mounted, "Type: A" is displayed. *2 If the SPARC64 X+ processor is mounted, "3.700 GHz; Type:0x20" is displayed. If the SPARC64 X processor is mounted, "3.000 GHz; Type:0x10" is displayed. |
- Confirm that no FRU has an asterisk (*) displayed in front of it.
The asterisk (*) is a mark indicating the abnormal state of an FRU, where an error or degradation occurred.
If a failure has occurred in any unit, see "A.2.2 Checking the contents of logs" and "A.2.3 Checking information on a component where a failure or degradation occurred." - Execute the showhardconf -u command.
The command displays the quantities of mounted FRUs. However, it does not display the quantities of I/O-related components such as PCIe cards and PCI expansion units while the system power is off.
- Example: SPARC M10-4S display example
XSCF> showhardconf -u SPARC M10-4S; Memory_Size:2048 GB; +-----------------------------------+------------+ | FRU | Quantity | +-----------------------------------+------------+ | BB | 2 | | CMUL | 2 | | Type:B | ( 2) | | CPU | 4 | | Freq:3.700 GHz; | ( 4) | | MEM | 64 | | Type:07; Size:16 GB; | ( 64) | | CMUU | 2 | | Type:B | ( 2) | | CPU | 4 | | Freq:3.700 GHz; | ( 4) | | MEM | 64 | | Type:07; Size:16 GB; | ( 64) | | PCICARD | 3 | | LINKCARD | 0 | | PCIBOX | 0 | | IOB | 0 | | LINKBOARD | 0 | | PCI | 0 | | FANBP | 0 | | PSU | 0 | | FAN | 0 | | XBU | 4 | | Type:A | ( 4) | | OPNL | 2 | | PSUBP | 2 | | Type:B | ( 2) | | PSU | 4 | | Type:B | ( 4) | | FANU | 10 | | XBBOX | 0 | | XBU | 0 | | XSCFU | 0 | | OPNL | 0 | | XBBPU | 0 | | XSCFIFU | 0 | | PSU | 0 | | FANU | 0 | +-----------------------------------+------------+ |
- Execute the showlogs error command.
Confirm that no error is displayed. If an error is displayed, see "A.2.2 Checking the contents of logs."
XSCF> showlogs error |
- Execute the showstatus command.
When there is no problem, the command displays nothing.
If a failure has occurred in any unit, an asterisk (*) and the unit status are displayed. See "A.2.3 Checking information on a component where a failure or degradation occurred."
XSCF> showstatus |
- To implement the initial system settings, go to "Chapter 7 Making the Initial System Settings." Otherwise, log out of the XSCF.