D.2 From Installation to Initial Diagnosis of Configuration With Direct Connections Between Chassis
D.2 From Installation to Initial Diagnosis of Configuration With Direct Connections Between Chassis
Work Description | Check | Checked By | Installation Guide Reference | |
---|---|---|---|---|
1. | Before installing the system, check the safety precautions, system specifications, and necessary conditions for installation. | [ ] | "Chapter 2 Planning and Preparing for System Installation" | |
2. | Prepare the necessary tools/information for installation. | [ ] | "3.1 Preparing the Necessary Tools/Information for Installation" | |
3. | Confirm the delivered components. When setting up the BB configuration at the delivery site, confirm the set BB-ID on the operation panel. (*1) |
[ ] | "3.2.1 Confirming the Delivered Components of the SPARC M12-2S" | |
[ ] | "3.2.2 Confirming the Delivered Components of the PCI Expansion Unit" | |||
4. | Install the rack. | [ ] | "2.4.1 Mounting Conditions for General Racks" | |
5. | Mount the SPARC M12-2S in the rack. | [ ] | "3.4.1 Mounting the SPARC M12-2S in a Rack" | |
6. | If there is a PCI expansion unit, mount it in the rack. | [ ] | "3.4.2 Mounting the PCI Expansion Unit in a Rack" | |
7. | After mounting the SPARC M12-2S, confirm the complete contact (complete engagement) of the internal storage, fan unit, and PCI cassettes. At this time, confirm that the PCI cassette lever is locked. |
[ ] | ||
8. | If there are optional components, mount them in the SPARC M12-2S and the PCI expansion unit. (For details, see the service manual.) |
[ ] | "3.5.1 Mounting Optional Components in the SPARC M12-2S" "3.5.2 Mounting Optional Components in the PCI Expansion Unit" Fujitsu SPARC M12-2/M12-2S Service Manual "Chapter 12 Maintaining PCIe Cards" "Chapter 15 Maintaining Internal Storage" "Chapter 17 Maintaining the CPU Memory Unit and Memory" |
|
9. | Check the identification ID of each SPARC M12-2S. | [ ] | "Chapter 4 Setting the SPARC M12-2S in a Building Block Configuration" "4.1 Setting the ID (BB-ID) Identifying the SPARC M12-2S" |
|
10. | Connect the XSCF BB control cable and the XSCF DUAL control cable to each SPARC M12-2S. | "4.2 Connecting XSCF Cables" | ||
11. | Connect the crossbar cable to each SPARC M12-2S. | "4.4 Storing Crossbar Cables" | ||
12. | Connect the serial cable (*2) and LAN cables to the SPARC M12-2S. Attach the core to the power cord, and connect the power cord to the power supply unit. |
[ ] | "5.1 Connecting Cables to the SPARC M12-2S" | |
13. | Connect the link cables and management cable to the PCI expansion unit and the SPARC M12-2S. Attach the core to the power cord, and connect the power cord to the PCI expansion unit. |
[ ] | "5.2 Connecting Cables to the PCI Expansion Unit" | |
14. | Store the cables connected to the SPARC M12-2S in the rack. Check the rack in use, and store them in a way that is appropriate for the rack. | [ ] | "5.4 Storing Cables" "4.4.1 When the Rack Width is 700 mm" "4.4.2 When the Rack Width is 600 mm" |
|
15. | Connect the system management terminal to the SPARC M12-2S of the master XSCF. | [ ] | "6.1 Connecting the System Management Terminal" | |
16. | Check the BB-ID setting. | [ ] | "6.2.1 Checking the BB-ID Settings" | |
17. | Turn on the input power, and check the status from the LED display on the XSCF unit. | [ ] | "6.2.2 Turning On the Input Power and Starting the XSCF" | |
18. | Log in to the master XSCF. | [ ] | "6.3 Logging In to the XSCF" | |
19. | Check the version of the XCP firmware. | [ ] | "6.4 Confirming the XCP Firmware Version" | |
20. | Set the altitude. | [ ] | "6.5 Checking the Altitude Setting" | |
21. | Set the time. | [ ] | "6.6 Setting the Time" | |
22. | Perform the initial diagnosis test. (*3) | [ ] | "6.7 Performing a Diagnosis Test" | |
23. | Confirm that each component is normally recognized and that no errors occur. | [ ] | "6.8 Checking the Component Status" | |
*1 Be sure to confirm the set BB-ID on the SPARC M12-2S operation panel before connecting and powering on the SPARC M12-2S with a BB configuration at the delivery site. The BB-ID will not be updated if only the BB-ID on the operation panel is changed. Be sure to connect the SPARC M12-2S with the set BB-ID on the operation panel. *2 Connect the serial cable to the serial port of the SPARC M12-2S operating as the master XSCF. *3 The probe-scsiall command and the show-devs command are displayed as command options in the diagnosis test. Confirm that the capacity and number of mounted disk units and the mounting locations and device names of the PCIe cards are correct. |