A.2.2 Checking the Contents of Logs
A.2.2 Checking the Contents of Logs
Use the showlogs command to check error logs.
showlogs command
The showlogs command displays the specified log. By default, the command displays the log in chronological order from the oldest time stamp. You can specify the following logs.
On individual systems, specify the type of log to display from the collected logs. You can specify one of the following:
On individual systems, specify the type of log to display from the collected logs. You can specify one of the following:
- error: Error log
- power: Power log
- event: Event log
- monitor: Monitoring message log
On individual SPARC M12-2S chassis, specify the type of log to display from the collected logs.
- env: Temperature history
On individual physical partitions (PPARs), specify the type of log to display from the collected logs. You can specify one of the following:
- console: Console message log
- panic: Panic message log
- ipl: IPL message log
Example: Display example where an XSCF cable is incorrectly connected
XSCF> showlogs error Date: Sep 29 16:35:09 JST 2016 Code: 80000000-003bff0000ff0000ff-01a100040000000000000000 Status: Alarm Occurred: Sep 29 16:35:01.895 JST 2016 FRU: /BB#1 Msg: BB control cable detected unexpected |
Example: Display example where crossbar cables are incorrectly connected as shown in Figure A-1
XSCF> showlogs error Date: Nov 08 11:01:37 JST 2012 Code: 10000008-007cff0000ff0000ff-019204310000000000000000 Status: Information Occurred: Nov 08 11:01:32.813 JST 2012 FRU: /BB#1/XBU#0/CBL#0R Msg: Cable connection test failure Date: Nov 08 11:01:38 JST 2012 Code: 10000008-007cff0000ff0000ff-019204310000000000000000 Status: Information Occurred: Nov 08 11:01:32.839 JST 2012 FRU: /BB#1/XBU#0/CBL#0L Msg: Cable connection test failure Date: Nov 08 11:01:43 JST 2012 Code: 10000008-007cff0000ff0000ff-019204310000000000000000 Status: Information Occurred: Nov 08 11:01:33.411 JST 2012 FRU: /BB#0/XBU#0/CBL#0R Msg: Cable connection test failure Date: Nov 08 11:01:44 JST 2012 Code: 10000008-007cff0000ff0000ff-019204310000000000000000 Status: Information Occurred: Nov 08 11:01:33.617 JST 2012 FRU: /BB#0/XBU#0/CBL#0L Msg: Cable connection test failure |
|