6.1 Connecting the System Management Terminal


6.1 Connecting the System Management Terminal
This section describes the procedures for checking the terminal software settings of the system management terminal and connecting the system management terminal to the serial port of the XSCF unit.
  1. Confirm that the terminal software for connecting the system management terminal has the following setting values.
Table 6-1  Terminal Software Setting Values
Setting Item Value
Baud rate 9600
Data length
8 bits
Parity None
STOP bit
1 bit
Flow control None
Delay Other than 0
  1. Confirm that the system management terminal is connected to the serial port of the XSCF unit.
    For a building block configuration, confirm that the terminal is connected to the serial port of the master XSCF.
Note - For direct connections between chassis, BB#00 is usually the master XSCF, and BB#01 is the standby XSCF. In the case of connections via a crossbar box, XBBOX#80 is usually the master XSCF, and XBBOX#81 is the standby XSCF. If the master is switched, BB#01 becomes the master XSCF, and BB#00 becomes the standby XSCF. For the mounting locations of BB#00 and BB#01, see Figure 2-2 in "2.4.1 Mounting Conditions for General Racks."