Table D-1  Work Descriptions and References (1BB Configuration)
Work Description Check Checked By Installation Guide Reference
1. Before installing the system, check the safety precautions, system specifications, and necessary conditions for installation. [   ]   "Chapter 2 Planning and Preparing for System Installation"
2. Prepare the necessary tools/information for installation. [   ]   "3.1 Preparing the Necessary Tools/Information for Installation"
3. Confirm the delivered components. [   ]   "3.2.1 Confirming the Delivered Components of the SPARC M12-2S"
    [   ]   "3.2.2 Confirming the Delivered Components of the PCI Expansion Unit"
4. Install the rack. [   ]   "2.4.1 Mounting Conditions for General Racks"
5. Mount the SPARC M12-2S in the rack. [   ]   "3.4.1 Mounting the SPARC M12-2S in a Rack"
6. If there is a PCI expansion unit, mount it in the rack. [   ]   "3.4.2 Mounting the PCI Expansion Unit in a Rack"
7. After mounting the SPARC M12-2S, confirm the complete contact (complete engagement) of the internal storage, fan unit, and PCI cassettes.
At this time, confirm that the PCI cassette lever is locked.
[   ]    
8. If there are optional internal components, mount them in the SPARC M12-2S and the PCI expansion unit.
(For details, see the service manual.)
[   ]   "3.5.1 Mounting Optional Components in the SPARC M12-2S"
"3.5.2 Mounting Optional Components in the PCI Expansion Unit"

Fujitsu SPARC M12-2/M12-2S Service Manual
"Chapter 12 Maintaining PCIe Cards"
"Chapter 15 Maintaining Internal Storage"
"Chapter 17 Maintaining the CPU Memory Unit and Memory"
9. Connect the serial cable and LAN cables to the SPARC M12-2S.
Attach the core to the power cord, and connect the power cord to the power supply unit.
[   ]   "5.1 Connecting Cables to the SPARC M12-2S"
10. Connect the link cables and management cable to the PCI expansion unit and the SPARC M12-2S.
Attach the core to the power cord, and connect the power cord to the PCI expansion unit.
[   ]   "5.2 Connecting Cables to the PCI Expansion Unit"
11. Store the cables connected to the SPARC M12-2S in the rack. Check the rack in use, and store them in a way that is appropriate for the rack. [   ]   "5.4 Storing Cables"
"4.4.1 When the Rack Width is 700 mm"
"4.4.2 When the Rack Width is 600 mm"
12. Connect the system management terminal to the SPARC M12-2S. [   ]   "6.1 Connecting the System Management Terminal"
13. Turn on the input power, and check the status from the LED display on the XSCF unit. [   ]   "6.2.2 Turning On the Input Power and Starting the XSCF"
14. Log in to the XSCF. [   ]   "6.3 Logging In to the XSCF"
15. Check the version of the XCP firmware. [   ]   "6.4 Confirming the XCP Firmware Version"
16. Set the altitude. [   ]   "6.5 Checking the Altitude Setting"
17. Set the time. [   ]   "6.6 Setting the Time"
18. Perform the initial diagnosis test. (*1) [   ]   "6.7 Performing a Diagnosis Test"
19. Confirm that each component is normally recognized and that no errors occur. [   ]   "6.8 Checking the Component Status"
*1 The probe-scsiall command and the show-devs command are displayed as command options in the diagnosis test. Confirm that the capacity and number of mounted disk units and the mounting locations and device names of the PCIe cards are correct.