Table 2-9 to Table 2-13 list the electrical specifications of the SPARC M12-2S and PCI expansion unit.
Note - The values listed in Table 2-9 to Table 2-13 are based on values for the maximum configurations of the SPARC M12-2S and PCI expansion unit. The actual values vary depending on the system configuration. |
Item | SPARC M12-2S (16 memory slots) | SPARC M12-2S (24 memory slots) |
---|---|---|
Input voltage | 200 to 240 VAC |
200 to 240 VAC |
Number of power cords | 4 (1 for each PSU) |
4 (1 for each PSU) |
Power cord length | Maximum length of 3.0 m (9.8 ft.) | Maximum length of 3.0 m (9.8 ft.) |
Redundancy | 2+2 redundant configuration | 2+2 redundant configuration |
Frequency | 50 Hz/60 Hz, single phase |
50 Hz/60 Hz, single phase |
Maximum input current (*1) | 16.5 A | 16.8 A |
Maximum power consumption | 3,224 W | 3,292 W |
Apparent power | 3,290 VA | 3,359 VA |
Rush current (*2) | 65 A peak or less | 65 A peak or less |
Leakage current (*2) | 3.5 mA or less | 3.5 mA or less |
*1 The current that flows through each power cord is a fraction of the value listed in Table 2-9. In a redundant configuration, it is one-fourth the value. In a non-redundant configuration, it is up to one-half the value. *2 The value is per power cord. |
Item | Specification | |
---|---|---|
Expansion Rack 1 Only | Available for Expansion Rack 2 | |
Input voltage | 200 to 240 VAC |
200 to 240 VAC |
Number of power cords | 8 | 8 |
Power cord length | 4.0 m (13.1 ft.) | 4.0 m (13.1 ft.) |
Redundancy (*2) | 1+1 redundant configuration | 1+1 redundant configuration |
Frequency | 50 Hz/60 Hz |
50 Hz/60 Hz |
Maximum input current (*3) | Max. 40 A | Maximum of 40 A |
Maximum input current (*4) (*5) | 6.9 A | 9.0 A |
Maximum power consumption (*4) | 1,354 W | 1,754 W |
Apparent power (*4) | 1,382 VA | 1,790 VA |
Rush current (*3) (*4) | 80 A peak or less |
80 A peak or less |
Leakage current (*3) (*4) | 3.5 mA or less | 3.5 mA or less |
*1 This shows the value for one rack. *2 In the case where the SPARC M12-2S is mounted in the expansion rack. When any unit other than SPARC M12-2S is mounted, the value may vary with the power connection configuration of the unit. *3 The value is the permissible value per power cord. The actual current value depends on the rated value of the devices mounted in the expansion rack. *4 This is the value when no SPARC M12-2S or other device is mounted in the expansion rack (only the crossbar box is mounted). Only two power cords consume power. If the SPARC M12-2S and other devices are mounted, the current value and the number of power cords consuming power may vary. *5 The current that flows through each power cord in a redundant configuration is half the value listed in Table 2-10. |
Item | Specification | |
---|---|---|
Expansion Rack 1 Only | Available for Expansion Rack 2 | |
Input voltage | 200 to 240 VAC |
200 to 240 VAC |
Number of power cords | 6 | 6 |
Power cord length | 4.0 m (13.1 ft.) | 4.0 m (13.1 ft.) |
Redundancy (*2) | 1+1 redundant configuration | 1+1 redundant configuration |
Frequency | 50 Hz/60 Hz |
50 Hz/60 Hz |
Maximum input current (*3) | Max. 35 A | Maximum of 35 A |
Maximum input current (*4) (*5) | 4.0 A | 5.2 A |
Maximum power consumption (*4) | 1,354 W | 1,754 W |
Apparent power (*4) | 1,382 VA | 1,790 VA |
Rush current (*3) (*4) | 80 A peak or less |
80 A peak or less |
Leakage current (*3) (*4) | 3.5 mA or less | 3.5 mA or less |
*1 This shows the value for one rack. *2 In the case where the SPARC M12-2S is mounted in the expansion rack. When any unit other than SPARC M12-2S is mounted, the value may vary with the power connection configuration of the unit. *3 The value is the permissible value per power cord. The actual current value depends on the rated value of the devices mounted in the expansion rack. *4 This is the value when no SPARC M12-2S or other device is mounted in the expansion rack (only the crossbar box is mounted). Only two power cords consume power. If the SPARC M12-2S and other devices are mounted, the current value and the number of power cords consuming power may vary. *5 The current that flows through each power cord in a redundant configuration is half the value listed in Table 2-11. |
Item | Specification | |
---|---|---|
Expansion Rack 1 Only | Available for Expansion Rack 2 | |
Input voltage | 380 to 415 VAC |
380 to 415 VAC |
Number of power cords | 6 | 6 |
Power cord length | 4.0 m (13.1 ft.) | 4.0 m (13.1 ft.) |
Redundancy (*2) | 1+1 redundant configuration | 1+1 redundant configuration |
Frequency | 50 Hz/60 Hz |
50 Hz/60 Hz |
Maximum input current (*3) | Max. 24 A | Maximum of 24 A |
Maximum input current (*4) (*5) | 2.1 A | 2.7 A |
Maximum power consumption (*4) | 1,354 W | 1,754 W |
Apparent power (*4) | 1,382 VA | 1,790 VA |
Rush current (*3) (*4) | 80 A peak or less |
80 A peak or less |
Leakage current (*3) (*4) | 3.5 mA or less | 3.5 mA or less |
*1 This shows the value for one rack. *2 In the case where the SPARC M12-2S is mounted in the expansion rack. When any unit other than SPARC M12-2S is mounted, the value may vary with the power connection configuration of the unit. *3 The value is the permissible value per power cord. The actual current value depends on the rated value of the devices mounted in the expansion rack. *4 This is the value when no SPARC M12-2S or other device is mounted in the expansion rack (only the crossbar box is mounted). Only two power cords consume power. If the SPARC M12-2S and other devices are mounted, the current value and the number of power cords consuming power may vary. *5 The current that flows through each power cord in a redundant configuration is half the value listed in Table 2-12. |
Item | Specification | |
---|---|---|
Input Voltage of 100 to 120 VAC | Input Voltage of 200 to 240 VAC | |
Number of power cords | 2 (1 for each PSU) |
2 (1 for each PSU) |
Power cord length | Maximum length of 3.0 m (9.8 ft.) | Maximum length of 3.0 m (9.8 ft.) |
Redundancy | 1+1 redundant configuration | 1+1 redundant configuration |
Frequency | 50 Hz/60 Hz, single phase |
50 Hz/60 Hz, single phase |
Maximum input current (*1) | 2.9 A | 1.4 A |
Maximum power consumption | 279 W | 270 W |
Apparent power | 284 VA |
276 VA |
Rush current (*2) | 40 A peak or less |
40 A peak or less |
Leakage current (*2) | 1.75 mA or less | 1.75 mA or less |
*1 The current that flows through each power cord in a redundant configuration is half the value listed in Table 2-13. *2 The value is per power cord. |
< Previous Page | Next Page >