A.2.3 Checking Information on a Component Where a Failure or Degradation Occurred
A.2.3 Checking Information on a Component Where a Failure or Degradation Occurred
Use the showstatus command to check information on a degraded unit among the FRUs composing the system.
showstatus command
The command displays information on each unit where a failure has occurred and the units on higher layers, from among the field replaceable units composing the system. The mark indicating the status (*) appears at the beginning of the line of the displayed unit. Status displays the unit status.
- Status: Description
- Faulted: Non-operational status of the relevant component due to failure
- Degraded: A part of the unit has failed, but the unit continues in operation.
- Deconfigured: Including its components on the lower layers, the unit is in a normal condition, but it has been degraded due to the influence of a failure or degradation of another unit.
- Maintenance: Maintenance work in progress. The addfru command, replacefru command, or initbb command is in operation.
Example: Display example where a CPU and memory of the CPU memory unit (lower) of BB#00 are degraded because of a failure
XSCF> showstatus BB#00; CMUL Status:Normal; * CPU#0 Status:Faulted; * MEM#00A Status:Faulted; |
< Previous Page | Next Page >